5. Appendix: Fax Service Program
Set CNG send time interval
Some machines on the receiving side may not be able to automatically switch the 3-second CNG
interval.
0-7
High order bit
Low order bit
G3 Switch 0F [SP No. 1-105-016]
No
Alarm when an error occurred in
5
Phase C or later
0
0: Disabled
1: Enabled
Alarm when the handset is off-hook
at the end of communication
1
0: Disabled
1: Enabled
2-3 Not used
Sidaa manual calibration setting
4
0: Off
1: On
5-6 Not used
IP Fax Switches
IP Fax Switch 00 [SP No. 1-111-001]
No.
0
Not used
200
FUNCTION
FUNCTION
3000-2250ms: 3000-50xNms
3000 – 50 x Nms 0F (3000 ms) < N < FF (2250 ms)
00-0E(3000-3700ms: 3000+50xNms
3000 – 50 x Nms 0F (3000 ms) < N < 0F (3700 ms)
COMMENTS
If the customer wants to hear an alarm after each error
communication, change this bit to "1".
If the customer wants to hear an alarm if the handset is off-
hook at the end of fax communication, change this bit to
"1".
Do not change the settings.
1: manually calibrates for communication with a line,
whose current change occurs such as an optical fiber line.
Do not change the settings.
Do not change this setting.