Rep 3.0.6 Outer Duplex Guide; Rep 3.0.7 Exit Module (8860Mfp) - Xerox Phaser 8860 Service Manual

Table of Contents

Advertisement

REP 3.0.6 Outer Duplex Guide

Parts List on
PL 3.0
Removal
NOTE: These steps describe Outer Duplex Guide removal for the 8860MFP. On 8860 models,
access the Outer Duplex Guide by removing the Control Panel
to this procedure and begin at Step 2.
1.
Remove the Output Tray
(REP
1.0.6).
2.
Remove the Left Side Cover
(REP 1.0.7
3.
Remove the Right Side Cover
(REP 1.0.21
4.
Disconnect the Front Door
P/J140
8860MFP and remove the guide. For 8860 models, these connections are made on the
Control Panel
(Figure
12).
5.
Remove the 4 (plastic, T-20) screws that secure the Outer Duplex Guide.
Figure 1 Removing the Outer Duplex Guide
Repairs and Adjustments
REP 3.0.6, REP 3.0.7
(REP
1.1.6). Afterwards, return
or
REP 1.1.9
for the 8860).
or
REP 1.1.10
for the 8860).
and Exit Door
P/J411
Interlock Switches on the

REP 3.0.7 Exit Module (8860MFP)

Parts List on
PL 3.0
Removal
1.
Remove the Scanner Assembly with attached DADF
2.
Remove the Output Tray
(REP
3.
Remove the Left Side Cover
4.
Remove the Right Side Cover
5.
Remove the Ink Loader
(REP
6.
Remove these components from the right side:
a.
Remove the right front (plastic, T-20) screw.
b.
Remove the KL-Clip, Pulley, and Belt from the Exit Elevator Roller to access and
remove the right rear screw located behind the large Wiper Assembly gear.
Figure 1 Exit Module Right Side Fasteners
09/2007
4-46
(REP
1.0.11).
1.0.6).
(REP
1.0.7).
(REP
1.0.21).
2.0.1).
Phaser 8860/8860MFP Service Manual
Initial Issue

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Phaser 8860mfp

Table of Contents