13,00x.6x Thermal Program Faults

A software error has occurred. The following troubleshooting procedure applies to these errors:
X-Axis Program Faults
13,001.62 Thermals failed to read system NVRAM.
13,002.63 Value not in valid range.
13,003.64 Thermal control task received an unexpected message.
13,004.65 Thermal control task was expecting initialization message, but received other.
13,005.66 Thermal code tried to command a segment ID that did not exist.
13,006.67 Thermal code tried to command a segment ID that did not exist.
13,007.68 Thermal power manager expected an initialization message, but received other.
13,008.60 Thermal power manager task received an unexpected message.
Initial Actions
Reset NVRAM and retest.
If the problem persists, follow the procedure below.
Primary Causes
The troubleshooting table lists parts and wiring referenced in the troubleshooting procedure.
Table 1 6,0xx.6x Troubleshooting Reference Table
Applicable Parts
Wiring and Plug/Jack References
NVRAM,
PL 5.0
Troubleshooting Procedure
Table 2 X-Axis Program Faults Troubleshooting Procedure
Step Questions or Actions
1
Reseat all Electronics Module connec-
tions.
Does the problem persist?
2
Check ground integrity.
Are the system grounds connected?
Error Messages and Codes
13,00x.6x, 19,0XX.4x
Yes
No
Go to Step 2.
Complete.
Reset NVRAM. If the
Reconnect the sys-
error persists,
tem grounds.
replace the NVRAM
device
(REP
5.0.9).

19,0XX.4x Printhead Calibration Faults

The root problem for this error is temperature sensitivity with the power supply's opto-isolator
chips. The following troubleshooting procedure applies to this error:
Printhead Calibration Faults
19,001.46
The HFD server failed due to NVRAM operation. THis fault should only occur
when the system is in manufacturing mode.
19,002.47
The system attempted a Printhead operation without position data in NVRAM.
19,003.48
Scale and offset voltage error too large. Something is wrong with the Electron-
ics Module or Wave Amplifier.
19,004.40
The Printhead and Electronics Module do not match.
19,005.41
Improper ground connection
Initial Actions
Check electrical connections to the Printhead.
Check for obstructions or damage near the Printhead. If obstructions are cleared, retest.
If the problem persists, follow the procedure below.
Primary Causes
The troubleshooting table lists parts and wiring referenced in the troubleshooting procedure.
Table 1 19,0xx.4x Troubleshooting Reference Table
Applicable Parts
Wiring and Plug/Jack References
Electronics Module,
PL 5.0
Electronics Module -
Printhead,
PL 2.0
Electronics Module -
Troubleshooting Procedure
Table 2 Process Drive Faults 7,0xx.4x Troubleshooting Procedure
Step Questions or Actions
1
Check and reseat all connections to the
Printhead.
Does the problem persist?
09/2007
2-32
Figure 8
Figure 8
Yes
No
Replace the Print-
Complete.
head
(REP
2.0.2). If
the error persists,
replace the Electron-
ics Module
(REP
5.0.5).
Initial Issue
Phaser 8860/8860MFP Service Manual