Configuring Rpm Probes For Bgp Monitoring - Juniper J-Series Administration Manual

Juniper networks router administration guide
Hide thumbs Also See for J-Series:
Table of Contents

Advertisement

Table 143: Tuning RPM Probes (continued)
Task
Set the time between probe
transmissions to 15 seconds.
Set the number of probes within a test
to
.
10
Set the source address for each probe
packet to
.
192.168.2.9
If you do not explicitly configure a
source address, the address on the
outgoing interface through which the
probe is sent is used as the source
address.
Configuring RPM Probes to Monitor BGP Neighbors
By default, the Services Router is not configured to send RPM probes to its BGP
neighbors. You must configure the BGP parameters under RPM configuration to send
RPM probes to BGP neighbors.
You can also direct the probes to a particular group of BGP neighbors.
This section contains the following topics:

Configuring RPM Probes for BGP Monitoring

This sample use of RPM for BGP monitoring uses a TCP probe. To use TCP or UDP
probes, you must configure both the probe server (Services Router) and the probe
receiver (the remote Services Router) to transmit and receive RPM probes on the
same TCP or UDP port. The sample probe uses TCP port 50000.
To configure RPM probes on a Services Router to monitor BGP neighbors with a
configuration editor:
1.
2.
3.
4.
J-Web Configuration Editor
In the Probe interval box, type
In the Probe count box, type
1.
In the Source address box, type
.
192.168.2.9
2.
Click OK.
Configuring RPM Probes for BGP Monitoring on page 283
Directing RPM Probes to Select BGP Routers on page 285
Navigate to the top of the configuration hierarchy in either the J-Web or CLI
configuration editor.
Perform the configuration tasks described in Table 144 on page 284.
If you are finished configuring the router, commit the configuration.
Go on to one of the following tasks:
To send probes to specific routers, see "Directing RPM Probes to Select BGP
Routers" on page 285.
Chapter 14: Configuring RPM Probes
CLI Configuration Editor
.
Enter
15
set probe-interval 15
.
Enter
10
set probe-count 10
Enter
set source-address 192.168.2.9
Configuring RPM with a Configuration Editor
283

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents