Table 92: Configuring Interface Alarms
Task
Navigate to the Alarm level in the
configuration hierarchy.
Configure the system to generate a red
interface alarm when a Yellow alarm is
detected on a T1 (DS1) link.
Configure the system to generate a red
interface alarm when a link down failure
is detected on an Ethernet link.
Configure the system to generate the
following interface alarms on a serial
link:
Yellow alarm when no CTS signal
is detected
Yellow alarm when no DCD signal
is detected
Red alarm when the receiver clock
is not detected
Red alarm when the transmission
clock is not detected
Configure the system to generate the
following interface alarms on a T3 link:
Red alarm when the remote
endpoint is experiencing a Red
failure
Yellow alarm when the upstream
bit stream has more consecutive
zeros than are permitted
Red alarm when there is a loss of
signal on the interface
J-Web Configuration Editor
1.
In the J-Web interface, select
Configuration>View and
Edit>Edit Configuration.
2.
Next to Chassis, click Configure or
Edit.
3.
Next to Alarm, click Configure or
Edit.
1.
In the Ds1 field, click Configure.
2.
From the the Ylw list, select red.
3.
Click OK.
1.
In the Ethernet field, click
Configure.
2.
From the Link down list, select red.
3.
Click OK.
1.
In the Serial field, click Configure.
2.
From the Cts absent list, select
yellow.
3.
From the Dcd absent list, select
yellow.
4.
From the Loss of rx clock list, select
red.
5.
From the Loss of tx clock list, select
red.
6.
Click OK.
1.
In the T3 field, click Configure.
2.
From the Ylw list, select red.
3.
From the Exz list, select yellow.
4.
From the Los list, select red.
5.
Click OK.
Configuring Alarms with a Configuration Editor
Chapter 9: Configuring and Monitoring Alarms
CLI Configuration Editor
From the
[edit]
hierarchy level, enter
edit chassis alarm
Enter
set ds1 ylw red
Enter
set ethernet link–down red
1.
Enter
set serial cts–absent yellow
2.
Enter
set serial dcd–absent yellow
3.
Enter
set serial loss–of–rx–clock red
4.
Enter
set serial loss–of–tx–clock red
1.
Enter
set t3 ylw red
2.
Enter
set t3 exz yellow
3.
Enter
set t3 los red