Sharp MX-FXX1 Service Manual page 48

Digital full color multifunctional system option facsimile expansion kit
Hide thumbs Also See for MX-FXX1:
Table of Contents

Advertisement

SW
Bit
Item
No.
No.
61
1-8
Setting of DTMF
minimum pause time
62
1-5
DTMF signal send time
6
Not used
7
DPMUTE control
8
Busy tone OFF non-
detection time
63
1-2
Lower limit of busy
tone ON detection time
3-4
Upper limit of busy
tone ON detection time
SW62, 6 Initial value
"0": North America/Australia/China/Singapore/Indonesia/Thailand/Malaysia/India/Philippine/Hong Kong/Taiwan/Middle East/Other3/Rusia
"1": U.K./France/Germany/Sweden/Finland/Norway/Denmark/Netherlands/Italy/Switcherland/Austria/New Zealand/Slovakia/South Africa/Spain/Portuguese/
Luxemburg/Belgium/Czech/Hungary/Greece/Poland
SW selection and function
This sets the minimum pause time between DTMF signals when
sending DTMF signals.
Minimum pause time can be set by binary inputting N over the range of
0 to 255 (1ms x N).
Setting can be made over the range of 50ms to 255ms in 1ms
increments by binary inputting.
The initial value is reverted to if a value outside of the setting range is
set.
This sets the time that DTMF signals are sent when sending DTMF
signals.
Send time can be set over the rage of 70 to 310ms in 10ms increments
by binary inputting N from 0 to 31 (110ms x N).
The initial value is reverted to if a value outside of the setting range is
set.
This sets whether or not to control the ports when sending the dial
pulse.
If the dial pulse dialing meets the difficulties, the setting must be
changed.
Functions only in Australia, New Zealand, U.K., France, Germany,
Sweden.
"0": OFF
"1": ON
This sets the non-detection time on the busy tone OFF section.
Change the setting in cases where noise, etc. on the busy tone ON
section adversely affects the ON section.
"0": 100ms
"1": 300ms
* Make shorter than the "busy tone OFF detection time."
This sets the lower limit time of the ON section when detecting
frequency of the busy tone signal.
If busy tone signals are not detected in excess of this time, do not count
as 1 pulse.
"00": 250ms
"01": 140ms
"10": 450ms
"11": 350ms
This sets the upper limit time of the ON section when detecting
frequency of the busy tone signal.
If busy tone signal is detected in excess of this time, do not count as 1
pulse.
"00": 750ms
"01": 650ms
"10": 1000ms
"11": 2850ms
MX-FXX1 SIMULATIONS, FAX SOFTWARE SWITCH 5 – 39
Initial value
0
120ms
Adjustment
value
1
1
1
1
0
0
0
0
110ms
1
0
1
1
0
Refer to "SW62, 6 Initial
value"
0
OFF
0
100ms
0
250ms (North America/
Australia/New Zealand/
0
China/Singapore/
Indonesia/Thailand/
Malaysia/India/Philippine/
Hong Kong/Taiwan/Middle
East/Other3/South Africa)
0
140ms (U.K./France/
Germany/Sweden/
1
Finland/Norway/Denmark/
Netherlands/Italy/
Switcherland/Austria/
Slovakia/Rusia/Spain/
Portuguese/Luxemburg/
Belgium/Czech/Hungary/
Greece/Poland)
0
"00": 750ms
(North America/U.K./
0
France/Germany/Sweden/
Finland/Norway/Denmark/
Netherlands/Italy/
Switcherland/Austria/New
Zealand/China/Indonesia/
Thailand/Malaysia/
Philippine/Hong Kong/
Taiwan/Middle East/
Slovakia/Other3/Rusia/
Spain/Portuguese/
Luxemburg/Belgium/
Czech/Hungary/Greece/
Poland)
"10": 1000ms
(Australia/India)
"11": 2850ms
(Singapore/South Africa)
System
settings

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents