LPOD Outdoor Amplifier / Block Up Converter
Ethernet-based Remote Product Management
Note: You must assign a unique IP Address for each unit on the network before connecting to an
existing network. As the IP address may need to be changed to something other than the factory
default setting, use the command IPA=xxx.xxx.xxx.xxx.yy, where: xxx.xxx.xxx.xxx is a valid IP
address on the network where the unit is to be installed, and yy is the range (typically, yy =
24).
Changing the IPA value requires that you cycle power on the unit, and then start a new
Telnet session using the new IP address.
See Chapter 5. SERIAL-BASED REMOTE PRODUCT MANAGEMENT for more information on the
LRS and IPA commands.

4.5.2 User Login

1. From the PC, type http://192.168.1.4 (the default IP address for the LPOD) into the Address
area of the browser:
2. The Login window will appear, similar to the example shown
here. Type the User name and Password, and then click [OK].
The default User Name and Password are both comtech.
Once the valid User Name
and Password is accepted,
the LPOD Web Server
Interface "splash" page
displays, as per the
example shown to the
right (note that the
Firmware Version listed
here is subject to change):
4–9
Revision 9
MN-LPOD