Comtech EF Data LPOD Installation And Operation Manual page 126

Outdoor amplifier / block up converter (buc)
Table of Contents

Advertisement

LPOD Outdoor Amplifier / Block Up Converter (BUC)
Serial-based Remote Product Management
Command
Arguments
(Instruction
for Command
Parameter Type
Code and
or Response
Qualifier)
to Query
Enable
ESW=
1 byte
Redundancy
Switch Mode
Retrieve Firmware
N/A
Number
Description of Arguments
(Note that all arguments are printable ASCII characters)
Command or Query.
Sets or returns the redundancy state in the form x, where:
0 = Off (default value)
1 = 1:1 Redundancy TX (Only TX switch installed)
2 = 1:1 Redundancy TX + RX (TX and RX switch installed)
5 = 1:1 Manual redundancy mode (used for debugging, or redundant system setup)(see Note)
Note: Manual redundancy does not support automatic switching, and the offline unit will not poll the online unit
to update its configuration.
Example: <1/ESW=1'cr'
>0001/ESW='cr''lf'
Query only
Returns the firmware type(s) loaded into the unit in the form FW-AAAAAAA B.B.BB DD/MM/YY, where:
FW-AAAAAAA = the firmware part number
B.B.BB = the version number
DD/MM/YY = Day/Month/Year firmware released
Example:
<1/FRW?'cr'
>0001/FRW=
Boot:
FW-0000082 0.0.1a 04/09/08
Bulk1:
FW-0000078 0.0.1a 04/09/08
FW-0000080 0.0.1a 04/09/08
FW-0000081 0.0.1a 04/09/08
Bulk2:
FW-0000078 0.0.1a 04/09/08
FW-0000080 0.0.1a 04/09/08
FW-0000081 0.0.1a 04/09/08
5–18
Revision 9
MN-LPOD
Response to
Query
Response to Query
Command
(Instruction
(Target to
(Target to
Code and
Controller)
Controller)
Qualifier)
ESW=
ESW?
ESW=x
ESW?
ESW *
FRW=
FRW?
FRW={CR}Boot:{CR}
abc{CR}Bulki:{CR}ab
c{CR}abc
(See Description of
Arguments)

Advertisement

Table of Contents
loading