Comtech EF Data LPOD Installation And Operation Manual page 122

Outdoor amplifier / block up converter (buc)
Table of Contents

Advertisement

LPOD Outdoor Amplifier / Block Up Converter (BUC)
Serial-based Remote Product Management
Command
Arguments
(Instruction
for Command
Parameter Type
Code and
or Response
Qualifier)
to Query
Concise
N/A
26 bytes
Configuration
Status
Concise RF Power
N/A
Length varies
FET Current
depending on
Status
number of
FETs installed
in the amplifier
Circuit
CID=
48 bytes
Identification
Description of Arguments
(Note that all arguments are printable ASCII characters)
Query only.
This is the concise version of the RCS query. Returns the configuration status of the unit, in the form
aa.aa;b;c;d;e;ff.ff;g;hhh, where:
aa.aa = attenuation in dB (ATT)
b = RF power amplifier state, 0 = Off, 1 = On (AMP)
c = mute state, 0 = un-muted, 1 = muted (MUT)
d = online status (ONL)
e = redundancy state and mode (ESW)
ff.ff = Attenuator offset in dB (AOF)
g = auto fault recovery mode (AFR)
hhh = External reference status, N/A = no external reference, 05M for 5 MHz, and 10M for a 10 MHz (See
Note)
Note: hhh will always be N/A if the internal reference oscillator option is not installed.
Example: CCS=aa.aa;b;c;d;e;ff.ff;g;hhh; 'cr''lf'
Query only.
This is the concise version of the RFS query. Returns the RF Power FET Current status.
Example: CFS=xxx,xxx,x.x,x.x,..........,x.x,
Command or Query.
Sets or returns a 48-byte user-defined string that identifies or names the unit or station. The CID is entered as
one line, but it reads back from the unit as two 24-byte lines of data.
Default value: ------------------------
Examples:
<1/CID= Station #001--SSPA #01--'cr'
>0001/CID=
<1/CID?'cr'
>0001/CID='cr'
Station #001'cr'
--SSPA #01--'cr''lf'
5–14
Revision 9
MN-LPOD
Response to
Query
Response to Query
Command
(Instruction
(Target to
(Target to
Code and
Controller)
Controller)
Qualifier)
CCS=
CCS?
CCS= aa.aa;b;c;d;e;
ff.ff;g;hhh
(See Description of
Arguments)
CFS=
CFS?
CFS=x.....x
(See description of
RFS. Note that each
argument is
separated by a
comma.)
CID=
CID?
CID=x...x
CID?
(See Description of
CID*
Arguments)

Advertisement

Table of Contents
loading