Comtech EF Data LPOD Installation And Operation Manual page 124

Outdoor amplifier / block up converter (buc)
Table of Contents

Advertisement

LPOD Outdoor Amplifier / Block Up Converter (BUC)
Serial-based Remote Product Management
Command
Arguments
(Instruction
for Command
Parameter Type
Code and
or Response
Qualifier)
to Query
Concise
N/A
95 bytes
Maintenance
Status
LNB Current
CWE=
1 bytes
Window Enable
Description of Arguments
(Note that all arguments are printable ASCII characters)
Query only.
This is the concise version of the RMS command. Returns the Maintenance status of the unit, response is
semicolon delimited, in the form aaa.a;bbb.b;ccc.c;ddd.d;eee.e;fff.f;ggg.g;hhh.h;iii.i;jjj.j;kkk.k;lll.l;mmm.m;nnn.n;
ooo.o;ppp.p;qqq.q;rrr.r;sss.s;ttt.t where:
aaa.a = P24V1
bbb.b = P24V2
ccc.c = LNBVT (see Note)
ddd.d = P13VT
eee.e=P10V1
fff.f = A10V1
ggg.g = A10V2 (see Note)
hhh.h = P7V8T
iii.i = P5V8T
jjj.j = P2V5T
kkk.k = P1V2T
lll.l = N5V8T
mmm.m = FANR1 (see Note)
nnn.n = FANR2 (see Note)
ooo.o = BUCVT (see Note)
ppp.p = FWPWR
qqq.q = REFVT (see Note)
rrr.r = LNBCS (see Note)
sss.s = ATEMP
ttt.t = OTEMP (see Note)
Note: ccc.c, ggg.g, mmm.m, nnn.n, ooo.o, qqq.q, rrr.r, and ttt.t will appear if the appropriate model/options have
been selected/installed. Otherwise, the unused fields will display XXXXX.
Example: <1/CMS?
>0001/CMS=aaa.a;bbb.b;ccc.c;ddd.d;eee.e;fff.f;ggg.g;hhh.h;iii.i;jjj.j;kkk.k;lll.l;mmm.m;nnn.n;ooo.o;ppp.p;qqq.q;
rrr.r;sss.s;ttt.t'cr''lf'
Command or Query.
Sets or returns the LNB current window alarm in the form x, where:
0=Disabled (default value)
1=Enabled (see Note)
Note: If disabled, the LCW value will be retained, but unused.
Example: <1/CWE=0'cr'
>0001/CWE='cr''lf'
5–16
Revision 9
MN-LPOD
Response to
Query
Response to Query
Command
(Instruction
(Target to
(Target to
Code and
Controller)
Controller)
Qualifier)
CMS=
CMS?
CMS=x....x
(See Description of
Arguments)
CWE =
CWE?
CWE =x
CWE?
(See Description of
CWE *
Arguments)

Advertisement

Table of Contents
loading