Comtech EF Data LPOD Installation And Operation Manual page 79

Outdoor amplifier / block up converter (buc)
Table of Contents

Advertisement

LPOD Outdoor Amplifier / Block Up Converter
Ethernet-based Remote Product Management
Configure HyperTerminal as follows:
1. Be sure to properly define the "Connect To" Telnet connection properties (File 
Properties), as shown below at the near right:
Enter the LPOD's
Management IP Address as
the Host Address (e.g.,
192.168.1.1).
Enter TCP Port 23 as the Port
number.
Set Connect using to TCP/IP
(Winsock) instead of COM1
or COM2.
2. For ASCII Setup (File  Properties  Settings  ASCII Setup), as shown above at the far
right:
A) Check the "Send line ends with line feeds" option in the ASCII Sending section.
B) Check the "Append line feeds to incoming line ends" option in the ASCII Receiving
section.
An example of login and remote command/query execution, when using HyperTerminal as the
interface, appears as follows:
4–7
Revision 9
MN-LPOD