LPOD Outdoor Amplifier / Block Up Converter (BUC)
Serial-based Remote Product Management
Command
Arguments
(Instruction
for Command
Parameter Type
Code and
or Response
Qualifier)
to Query
Terminal Status
N/A
1 byte
Change
External
XRM=
1 byte
Reference Mute
numeric
O
Description of Arguments
(Note that all arguments are printable ASCII characters)
Query only.
Indicates if there has been a change in the configuration since the last time a command was issued, in the form
x, where:
0 = no status change
1 = there has been a status change.
A status change is defined as any time a parameter is changed, such as when command that changes a value is
successfully executed. A status change also results when there is a redundant switchover, or a fault condition.
A query does not set the status change flag. The status change flag is cleared after being read.
Example: <1/TSC?'cr'
>0001/TSC=0'cr''lf'
Command or Query.
Sets or returns the external reference mute state in the form x, where:
0 = Disable
1 = Enable (see Note)
Note: To enable this command, the internal reference oscillator option must be installed; otherwise, a mode
error will result. A hardware mute condition generated by the XRM mute is one of the conditions that can cause
the MUT command to return MUT=2.
When enabled, the unit will mute if an external reference oscillator is not detected.
Example: <1/XRM=1'cr'
5–36
Revision 9
MN-LPOD
Response to
Query
Response to Query
Command
(Instruction
(Target to
(Target to
Code and
Controller)
Controller)
Qualifier)
TSC=
TSC?
TSC=x
(See Description of
Arguments)
XRM=
XRM?
XRM=x
XRM?
(See Description of
MSK*
Arguments)