Comtech EF Data LPOD Installation And Operation Manual page 125

Outdoor amplifier / block up converter (buc)
Table of Contents

Advertisement

LPOD Outdoor Amplifier / Block Up Converter (BUC)
Serial-based Remote Product Management
Command
Arguments
(Instruction
for Command
Parameter Type
Code and
or Response
Qualifier)
to Query
Set RTC (Real-
DAT=
6 bytes
Time-Clock) Date
E
Set RTC (Real-
DAY=
6 bytes
Time-Clock) Date
Enable Statistics
ESA=
1 byte
Averaging
Enable Statistics
ESL=
1 byte
Logging
Description of Arguments
(Note that all arguments are printable ASCII characters)
Command or Query.
Sets or returns the real-time clock date in the form mmddyy, where;
dd = day of the month, from 01 to 31,
mm = month of the year, from 01 to 12
yy = year, from 00 to 96 (2000 to 2096)
Example (date = April 24, 2003):
<1/DAT=042403'cr'
>0001/DAT='cr''lf'
Command or Query.
Sets or returns the real-time clock date in the form ddmmyy, where;
dd = day of the month, from 01 and 31,
mm = month of the year, from 01 to 12
yy = year, from 00 to 99 (2000 to 2099)
Example (date = April 24, 2003):
<1/DAY=240403'cr'
>0001/DAY='cr''lf'
Command or Query.
Enables or Disables averaging of statistics data at a rate of once per second for 10 seconds, in the form x,
where:
0 = Disable (default value)(see Note)
1 = Enable
Note: If Disabled, burst values will be logged instead of averaged values.
Example: <1/ESA=0'cr'
>0001/ESA='cr''lf'
Command or Query.
Sets or returns the statistics logging function in the form x, where:
0 = Disable (default value)
1 = Enable
Example: <1/ESL=1'cr'
>0001/ESL='cr''lf'
5–17
Revision 9
MN-LPOD
Response to
Query
Response to Query
Command
(Instruction
(Target to
(Target to
Code and
Controller)
Controller)
Qualifier)
DAT= mmddyy
DAT=
DAT?
DAT?
(See Description of
DAT*
Arguments)
DAY= ddmmyy (See
DAY=
DAY?
DAY?
Description of
DAY*
Arguments)
ESA=
ESA?
ESA=x
ESA?
(See Description of
ESA*
Arguments)
ESL=
ESL?
ESL=x
ESL?
(See Description of
ESL*
Arguments)

Advertisement

Table of Contents
loading

Table of Contents