LPOD Outdoor Amplifier / Block Up Converter
Ethernet-based Remote Product Management
Click [Refresh] (at the top of the page) to update the graphs to their current polled states.
Control Bar and Refresh Tab
Use the Control Bar to choose the time, date, and duration of the trending information
displayed on the graphs. The graphs are all tied to the same 'x' scale so that you can more easily
correlate data between the graphs.
Note the following:
Start Date (mm/dd/yy): Once a unit has been in operation for 24 hours or more, use the
drop-down list to select a date – up to a maximum of 28 days, including the present
date – from which to compile data. If a unit has not been in operation for 24 hours, only
present will be available.
Time: Once a unit has been in operation for 24
hours or more, use this drop-down list to select
the time on the hour – 24 hours, from 12 am to 11 pm, are available. Note that, for the
first 24 hours of operation (or beyond if the time has accrued), if you select present as
the Start Date, then the Time drop-down list becomes unavailable for selection and dim
as shown here.
Duration: Use the drop-down list to select the block of time in which data is compiled
for the graphs. Select 30 minutes, 1 hour, 2 hours, 4 hours, 6 hours, 8 hours, 12 hours,
24 hours, or 48 hours.
The trending data is stored to the unit's flash memory once per hour. If the unit
is powered off before the data can be written to memory, the last 60 minutes of
data will be lost.
Click [Submit] to execute the choice once the configuration parameters have been defined;
then, click the [Refresh] tab to update the graphs with the most current trending parameters
(note that when the page refreshes, the Power Graph resets to display the default unit of dBm).
4–32
Revision 9
MN-LPOD