Comtech EF Data LPOD Installation And Operation Manual page 135

Outdoor amplifier / block up converter (buc)
Table of Contents

Advertisement

LPOD Outdoor Amplifier / Block Up Converter (BUC)
Serial-based Remote Product Management
Command
Arguments
(Instruction
for Command
Parameter Type
Code and
or Response
Qualifier)
to Query
Reboot
RBT=
1 byte
Retrieve
N/A
45 bytes
Configuration
Status
Online Status
RED=
1 byte
Description of Arguments
(Note that all arguments are printable ASCII characters)
Command only.
Performs a soft reboot in the form x, where:
1 = Reboot System
Query only.
Returns the configuration status of the unit.
Examples:
RCS='cr'
ATT=12.75'cr'
AMP=1'cr'
MUT=1'cr'
ONL=1'cr'
ESW=1'cr'
AOF=00.00'cr'
AFR=1'cr'
XRF=N/A'cr''lf' (see Note)
Where:
ATT= attenuation in dB
AMP= RF power amplifier state, 0=OFF, 1=ON
MUT=RF mute state, 0=un-muted, 1=muted
RED=Online status for redundancy
ESW=Redundancy state and mode,
states: 0=OFF, 1=ON Tx only, 2=ON Tx & Rx
AOF=Attenuator Offset in dB
AFR= auto fault recovery, 0=manual, 1=auto
XRF = External reference status, N/A = no external reference, 05M for 5 MHz, and 10M for a 10 MHz
Note: XRF will always be N/A if the internal reference oscillator option is not installed.
Command or Query.
Sets or returns Redundancy Online status in the form x, where:
0 = Offline
1 = Online
Note: this command is functionally identical to the ONL command.
Example: <1/RED=1'cr'
>0001/RED='cr''lf'
5–27
Revision 9
MN-LPOD
Response to
Query
Response to Query
Command
(Instruction
(Target to
(Target to
Code and
Controller)
Controller)
Qualifier)
RBT =
N/A
RBT=x
RBT?
(See Description of
RBT*
Arguments)
RCS=
RCS?
RCS=x....x
(See Description of
Arguments)
RED=
RED?
RED=x
RED?
RED*

Advertisement