Comtech EF Data LPOD Installation And Operation Manual page 123

Outdoor amplifier / block up converter (buc)
Table of Contents

Advertisement

LPOD Outdoor Amplifier / Block Up Converter (BUC)
Serial-based Remote Product Management
Command
Arguments
(Instruction
for Command
Parameter Type
Code and
or Response
Qualifier)
to Query
Calibrate LNB
CLC=
none
Current
Clear Statistics
CSL=
1 byte
Log
Concise Utility
N/A
15 bytes
Status
E
Description of Arguments
(Note that all arguments are printable ASCII characters)
Command or Query.
Sets or returns, as a reference point, the value of the LNB Current Supply (in mA) in the form xxx.x.
Default value: 000.0
The LNB current alarm point is then determined by the calibrated LNB reference point, and the LNB current window
setting (see LCW command).
Note: this command will return a mode error if the LNB current source output has not been enabled first (see
LCS command).
Example: <1/CLC='cr'
>0001/CLC='cr''lf'
The CLC query will return the value that was stored during the LNB current calibration.
Example: <1/CLC?'cr'
>0001/CLC=xxx.x where xxx.x is the calibrated LNB current value in mA.
Command only.
Clears the statistics log entries. This command takes no arguments.
Example:
<1/CSL=1'cr'
>0001/CSL='cr''lf'
Query only.
Returns the Maintenance status of the unit, response is semicolon delimited, in the form aaaa;bbbbb;ccc where:
aaaa = Remote Unit Address
bbbbb = Remote Baud Rate
ccc = Reference oscillator tuning voltage DAC value (see Note)
Note: ccc is only present if a reference oscillator is installed.
Example:
<1/CUS?'cr'
>0001/CUS=aaaa;bbbbb;ccc;'cr''lf'
5–15
Revision 9
MN-LPOD
Response to
Query
Response to Query
Command
(Instruction
(Target to
(Target to
Code and
Controller)
Controller)
Qualifier)
CLC=
CLC?
CLC=xxx.x
CLC?
(See Description of
CLC*
Arguments)
CSL=
N/A
CSL=
CSL?
CSL*
CUS=
CUS?
CUS=x....x
(See Description of
Arguments)