Comtech EF Data LPOD Installation And Operation Manual page 131

Outdoor amplifier / block up converter (buc)
Table of Contents

Advertisement

LPOD Outdoor Amplifier / Block Up Converter (BUC)
Serial-based Remote Product Management
Command
Arguments
(Instruction
for Command
Parameter Type
Code and
or Response
Qualifier)
to Query
Maximum
N/A
272 bytes
Operating point
Description of Arguments
(Note that all arguments are printable ASCII characters)
Query only.
Returns the maximum operating point of the unit along with its timestamp
Reply format:
MAXFET=sYYYC mmddyy hhmmss'cr'
MINFET=sYYYC mmddyy hhmmss'cr'
MAXPFT=sYYYC mmddyy hhmmss'cr'
MAXDTP=sYYYC mmddyy hhmmss'cr'
MAXHTS=sYYYC mmddyy hhmmss'cr'
MINHTS=sYYYC mmddyy hhmmss'cr'
MAXOST=sYYYC mmddyy hhmmss'cr'
MAXRFP=sZZ.ZZ mmddyy hhmmss'cr'
MINRFP=sZZ.ZZ mmddyy hhmmss'cr'
Where:
sYYYC is the temperature
sZZ.ZZ is the power
Note: not all LPODs have outside temperature monitor. In that case, MAXOST and MINOST will report XXXXX
XXXXXX XXXXXX
Example: <1/MOP?'cr'
>0001/mop='cr'
MAXFET=+000C 010208 180729'cr'
MINFET=+000C 010208 180729'cr'
MAXPFT=+000C 010208 180659'cr'
MAXDTP=+000C 010208 180729'cr'
MAXHTS=+050C 010208 180729'cr'
MINHTS=+050C 010208 180729'cr'
MAXOST=XXXXX XXXXXX XXXXXX'cr'
MINOST=XXXXX XXXXXX XXXXXX'cr'
MAXRFP=+00.00 010208 180659'cr'
MINRFP=+00.00 010208 180659'cr'
5–23
Revision 9
MN-LPOD
Response to
Query
Response to Query
Command
(Instruction
(Target to
(Target to
Code and
Controller)
Controller)
Qualifier)
MOP=
N/A
(See Description of
Arguments)