LPOD Outdoor Amplifier / Block Up Converter (BUC)
Serial-based Remote Product Management
Command
Arguments
(Instruction
for Command
Parameter Type
Code and
or Response
Qualifier)
to Query
Offline Mute
OFM=
1 byte
Online Status
ONL=
1 byte
Part Number
N/A
Various 1-96
bytes
Description of Arguments
(Note that all arguments are printable ASCII characters)
Command or Query.
Sets or returns offline mute in the form x, where:
0 = Disable (Not Muted)
1 = Enable (Muted)
2 = Mute RX
3 = Mute Tx
4 = Mute Rx+LNB
5= Mute Tx+LNB
Note: LNB Voltage of Online unit shows on Status page of Offline unit when Offline Mute is set to 4 or 5. This is
caused by voltage feedback from Online unit to Offline unit via RF splitter.
Example: <1/OFM=1'cr'
>0001/OFM=1'cr''lf
Command or Query.
Sets or returns the Redundancy Online status in the form x, where:
0 = Offline (Query only) (see Note 2)
1 = Online
Notes:
1. The ONL query always returns an online response if the unit is not running in redundant mode. If redundancy is
enabled then the query will indicate the position of the Tx waveguide switch that enables one of the units to be
connected to the antenna.
2. Sending ONL=0 will not generate a syntax error; however setting ONL to zero will not cause the unit to go offline.
The online status is determined by the TX waveguide redundant switch position, and only the offline unit may
drive the switches. Instead of sending ONL=0 to the online unit the ONL=1 command should be sent to the
offline unit to generate a redundant switchover.
Example: <1/ONL=1'cr'
>0001/ONL='cr''lf'
Query only.
Returns the Comtech EF Data part number of the unit. This part number is the unit's DOTCODE at the time of
manufacture. The DOTCODE may be up to 96 printable ASCII characters long.
Example: <1/PNM?'cr'
>0001/PNM=HPODC0.350WRSW00'cr''lf'
5–25
Revision 9
MN-LPOD
Response to
Query
Response to Query
Command
(Instruction
(Target to
(Target to
Code and
Controller)
Controller)
Qualifier)
OFM=
OFM?
OFM=x
OFM?
ONL=
ONL?
ONL=x
ONL?
ONL*
PNM=
PNM?
PNM=x....x
(See Description of
Arguments)