Replacing The System Board; Preliminary Steps - Fujitsu PRIMERGY CX272 S1 Upgrade And Maintenance Manual

Server node
Hide thumbs Also See for PRIMERGY CX272 S1:
Table of Contents

Advertisement

9.3

Replacing the system board

Field Replaceable Unit
(FRU)
Tools: Phillips PH2 / (+) No. 2 screw driver, Phillips PH1 / (+) No. 1 screw
driver, tool-less
Note on system information backup / restore
I
The system board contains the Chassis ID EPROM that contains system
information like server name and model, housing type, serial number and
manufacturing data.
To avoid the loss of non-default BIOS settings before replacing the
system board, take notes of the important system configuration data by
hand. After replacing the system board set the system configuration data
in the BIOS setup menu by hand.
Note on network settings recovery
I
When replacing network controllers or the system board, network
configuration settings in the operating system will be lost and replaced
by default values. This applies to all static IP address and LAN teaming
configurations.
Ensure to note down your current network settings before replacing a
controller or the system board.
9.3.1

Preliminary steps

Perform the following steps:
"Disabling SVOM boot watchdog functionality" on page 75
Ê
Ê Locate the desired server with the ID button.
"Shutting down the server node" on page 41
Ê
Ê If applicable, remove all external cables from the server node.
"Removing the server node from the Dual Node Cluster Server" on page 42
Ê
CX272 S1
Upgrade and Maintenance Manual
System board and components
Hardware: 50 minutes
Software: 10 minutes
199

Advertisement

Table of Contents
loading