Software Configuration; Removing The Ufm Board; Preliminary Steps - Fujitsu PRIMERGY CX272 S1 Upgrade And Maintenance Manual

Server node
Hide thumbs Also See for PRIMERGY CX272 S1:
Table of Contents

Advertisement

9.2.1.4

Software configuration

The UFM delivery set includes the "Recovery Tool CD" to setup the ESXi
configuration. Proceed as follows:
Ê Switch on the server.
Ê Right after switching on the server, insert the "Recovery Tool CD" into the
DVD drive and close the drive tray.
Ê The server should now boot from the "Recovery Tool CD".
Ê Follow the on-screen instructions.
9.2.2

Removing the UFM board

Field Replaceable Unit
(FRU)
Tools: Phillips PH1 / (+) No. 1 screw driver
9.2.2.1

Preliminary steps

Perform the following procedures:
"Disabling SVOM boot watchdog functionality" on page 75
Ê
Ê Locate the desired server with the ID button.
"Shutting down the server node" on page 41
Ê
Ê If applicable, remove all external cables from the server node.
"Removing the server node from the Dual Node Cluster Server" on page 42
Ê
CX272 S1
Upgrade and Maintenance Manual
System board and components
Hardware: 5 minutes