Minimum startup configuration

Field Replaceable Unit (FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
System board
CPU with CPU heat sink
1 memory module
2 Power supply units
Table 15: Minimum startup configuration - components
Cable
2 SATA cables
Table 16: Minimum startup configuration - cables
Ê Shut down the server as described in section
node" on page
Ê Take the system down to its minimum startup configuration.
Ê Connect a keyboard, mouse and display to the server.
Ê Switch on the server as described in section
on page
73.
V
CAUTION!
Since the fan module is not included in the minimum startup
configuration, the server must be shut down immediately after the
diagnostic process is complete (POST phase has been passed).
232
Notes and reference
no UFM or expansion cards installed
installed in socket CPU0
installed in slot A1 or C1, see section
sequence" on page 142