Updating Or Recovering The Bmc - Fujitsu PRIMERGY CX272 S1 Upgrade And Maintenance Manual

Server node
Hide thumbs Also See for PRIMERGY CX272 S1:
Table of Contents

Advertisement

V
CAUTION!
Do not interrupt the BIOS recovery process after it has started. If the
process is interrupted, the system BIOS may be permanently
corrupted.
Ê After completion of the flash process, shut down the server.
Ê Remove the server node from the Dual Node Cluster Server as described in
section
"Removing the server node from the Dual Node Cluster Server" on
page
42.
Ê Disable BIOS recovery mode using the onboard jumpers:
I
For detailed information on jumper settings, refer to section
settings" on page
Ê Install the server node in the Dual Node Cluster Server
node in the Dual Node Cluster Server" on page
5.2.1.2

Updating or recovering the BMC

BMC flash procedure
I
For the Japanese market, follow the instructions provided separately.
Ê Prepare a USB stick including the bootable BMC firmware update image.
Ê Connect the USB stick to the USB port.
I
Ensure that only the USB device with the BMC firmware is connected
to the USB port. Remove all other USB devices temporarily.
Ê Restart the server.
Ê The system will detect the USB stick.
I
If the BIOS cannot identify the USB stick, the pop-up message
Failed to boot for Emergency flash. Please Reset now.
will show up in the center of the screen.
Ê Choose one of the following options from the update tool menu to start the
BMC update process:
Normal Choose this option to update an existing system board.
CX272 S1
226.
Upgrade and Maintenance Manual
Basic software procedures
"Installing the server
72.
"Onboard
79

Advertisement

Table of Contents
loading