V
CAUTION!
Do not interrupt the BIOS recovery process after it has started. If the
process is interrupted, the system BIOS may be permanently
corrupted.
Ê After completion of the flash process, shut down the server.
Ê Remove the server node from the Dual Node Cluster Server as described in
section
"Removing the server node from the Dual Node Cluster Server" on
page
42.
Ê Disable BIOS recovery mode using the onboard jumpers:
I
For detailed information on jumper settings, refer to section
settings" on page
Ê Install the server node in the Dual Node Cluster Server
node in the Dual Node Cluster Server" on page
5.2.1.2
Updating or recovering the BMC
BMC flash procedure
I
For the Japanese market, follow the instructions provided separately.
Ê Prepare a USB stick including the bootable BMC firmware update image.
Ê Connect the USB stick to the USB port.
I
Ensure that only the USB device with the BMC firmware is connected
to the USB port. Remove all other USB devices temporarily.
Ê Restart the server.
Ê The system will detect the USB stick.
I
If the BIOS cannot identify the USB stick, the pop-up message
Failed to boot for Emergency flash. Please Reset now.
will show up in the center of the screen.
Ê Choose one of the following options from the update tool menu to start the
BMC update process:
Normal Choose this option to update an existing system board.
CX272 S1
226.
Upgrade and Maintenance Manual
Basic software procedures
"Installing the server
72.
"Onboard
79