Basic software procedures
Ê Press the function key [F11] and select the bootable USB stick with the
arrow keys Ê and Ë.
Ê Change the directory with cd DOS and start the Flash BIOS Update with the
command DosFlash. Then follow the instructions on the screen.
Ê After the Flash BIOS Update the system is restarted automatically. The
system will be booted with the new BIOS revision.
Ê Check the settings in the BIOS setup utility. If necessary, reconfigure the
settings again.
BIOS recovery procedure
I
For the Japanese market, follow the instructions provided separately.
Ê Prepare a USB stick with the following files:
– Update tool
– Startup.nsh (which will execute the update tool)
– BIOS image file for update (16 MB with header information)
Ê Ensure that the server has been shut down and disconnected from the
mains as described in section
Ê Remove the server node from the Dual Node Cluster Server as described in
section
"Removing the server node from the Dual Node Cluster Server" on
page
42.
Ê Enter BIOS recovery mode using the onboard jumpers.
I
For detailed information on jumper settings, refer to section
settings" on page
Ê Install the server node in the Dual Node Cluster Server
node in the Dual Node Cluster Server" on page
Ê Connect the USB stick to the USB port.
Ê Connect the server to the mains as described in the Upgrade and
Maintenance Manual "PRIMERGY CX420 S1 Dual Node Cluster Server".
Ê Press the On / Off button to start up the server.
The system will detect the USB stick and the BIOS recovery process will be
performed.
78
"Shutting down the server node" on page
226.
Upgrade and Maintenance Manual
"Onboard
"Installing the server
72.
41.
CX272 S1