Solid state drives
6.5

Replacing an SSD module

Upgrade and Repair Units (URU)
Average hardware task duration: 15 minutes
Average software task duration: 5 minutes
V
CAUTION!
All SSD modules (drives) must be uniquely identified so that they can
be reinstalled in their original mounting locations later. If this is not
done, existing data can be lost.
6.5.1

Required tools

Preliminary and concluding steps: tool-less
Replacing an SSD module: Phillips PH2 / (+) No. 2 screw driver
6.5.2

Preliminary steps

Before replacing an SSD module, perform the following steps:
Ê Disable BitLocker functionality as described in section
functionality" on page
Ê If applicable, open the rack door as described in section
door" on page
Ê Locate the desired server blade as described in section
defective server blade" on page
Ê Shut down the server blade as described in section
server blade" on page
Ê Remove the server blade from the system unit as described in section
"Removing the server blade from the system unit" on page
Ê Open the server blade as described in section
on page
60.
122
73.
53.
54.
Upgrade and Maintenance Manual
45.
"Opening the server blade"
"Disabling BitLocker
"Opening the rack
"Locating the
"Shutting down the
59.
BX924 S3