Quick Steps for Configuring Switch Logging

Quick Steps for Configuring Switch Logging
1
Enable switch logging by using the following command:
-> swlog
2
Specify the ID of the application to be logged along with the logging severity level.
-> swlog appid bridge level warning
Here, the application ID specifies bridging and the severity is set to the "warning" level.
3
Specify the output device to which the switch logging information must be sent.
-> swlog output console
-> show swlog
-> show swlog
Operational Status
File Size per file
Log Device
Syslog FacilityID
Remote command-log
Hash Table entries age limit
Switch Log Preamble
Switch Log Debug
Switch Log Duplicate Detection
Console Display Level
page 28-4
: Running,
: 100K bytes,
: console flash,
: local0(16),
: Disabled,
: 60 seconds,
: Enabled,
: Disabled,
: Enabled,
: debug3,