Agilent Technologies N9340A User Manual page 106

Handheld spectrum analyzer
Hide thumbs Also See for N9340A:
Table of Contents

Advertisement

6
SCPI Command Reference
Define Limit Pattern Values
:CALCulate:LLINe[1]:DATA
<x-axis>,<ampl>{,<x-axis>,<ampl>}
:CALCulate:LLINe[1]:DATA?
This command defines limit pattern values, and
destroys all existing data. A N9340A allows you to
set as many as four points to compose the limit
pattern by connecting them together.
*RST State:
Key Access:
• <x-axis> – are values in frequency or time
domain as specified by
:CALCulate:LLINe[1]:PATtern:DOMain.
Domain
Frequency
Time
• <ampl> – amplitude values are in the current
Y- axis units. A N9340A provides you four
choices for Y- axis units: uV, mV, - dBm, dBm.
104
Off
[Limit] > {Set Pattern}
Valid Unit
Hz, kHz, MHz, GHz
us, ms, s, ks
N9340A User's Guide