Agilent Technologies 16702B Installation Manual

Logic analysis systems, measurement modules

Advertisement

Installation Guide
16700B
Measurement
Modules
16702B
Logic Analysis Systems
16allp01
Publication Number 16700-97014
© Copyright Agilent Technologies 2000
All Rights Reserved

Advertisement

Table of Contents
loading

Summary of Contents for Agilent Technologies 16702B

  • Page 1 Installation Guide 16700B Measurement Modules 16702B Logic Analysis Systems 16allp01 Publication Number 16700-97014 © Copyright Agilent Technologies 2000 All Rights Reserved...
  • Page 3: Table Of Contents

    Contents System Overview Agilent 16700B System Overview Agilent 16702B Mouse and Keyboard Monitor Connection Proper Cooling Monitor Configuration 16700B Monitor Configuration 16702B Changing Monitors Printers External Disk Drive External Disk Drive & CD-ROM Drive 19 Software Installation 16701A/B Expander Frame...
  • Page 4: System Overview Agilent 16700B

    16700B Overview 16700B Mainframe (If ordered) Monitor Monitor Cable Monitor Power Cable Power Cable Keyboard Training Board and Training Kit Mouse Additional Connections 16701A/B Expander Frame Printer External Disk Drive and Cable Cable (Data Drive - Option 008) (Boot Drive - Option 009) 16allp04...
  • Page 5: System Overview Agilent 16702B

    16702B Overview Training Board and Training Kit 16702B Mainframe Power Cable Mouse and Keyboard Additional Connections Monitor Monitor Cable and Monitor Power Cable (If ordered) External Disk Drive and Cable (Data Drive - Option 008) (Boot Drive - Option 009)
  • Page 6: Mouse And Keyboard

    Mouse & Keyboard for 16700B/ 16702B The 16700B must have the system mouse and keyboard connected for the system to boot up properly. Once enabled on the LAN, the system can be operated remotely without a keyboard or mouse. 16700B...
  • Page 7: Monitor Connection

    Monitor Connection for 16700B /16702B If applicable, international versions of the power cables can be found in the accessories box. Monitor & Power Cable (Optional for 16702B) 16700B 16702B Target Target Keyboard Mouse To 16701 Expansion Frame To 16701 Expansion Frame...
  • Page 8: Proper Cooling

    Proper Cooling for 16700B/ 16702B/ Measurement Modules Allow a minimum of 5 cm spacing between instruments for proper cooling. Power Busy >5cm >5cm 16700B Power Busy >5cm >5cm 16702B 16allp08...
  • Page 9: Monitor Configuration 16700B

    Monitor Configuration for 16700B If you ordered the optional monitor with your logic analyzer, the monitor resolution setting is pre- configured for 1280 x 1024 at the factory. If you already have a monitor and ordered your logic analysis system without the optional monitor, you will need to configure your monitor.
  • Page 10: Monitor Configuration 16702B

    Monitor Configuration for 16702B Use this procedure if you wish to configure an optional monitor to an 16702B. Monitor power System power Immediately press the TAB key about ten times. (Cycling choices) Press ENTER to select the monitor choice and "Y" to confirm.
  • Page 11: Changing Monitors

    Changing Monitors for 16700B/ 16702B (Different Monitor) Monitor power 16700B System power Immediately press the 16702B TAB key about ten times. Press ENTER to select the monitor choice and "Y" to confirm. (Cycling choices) Clear Images Enter Monitor choice. 16allp11...
  • Page 12: Lan

    16700B/ 16702B 10Base-T /100Base-TX Help Target Target Keyboard Keyboard Mouse To 16701 Expansion Frame To 16701 Expansion Frame Control Control 16700B or 16702B 16allp12...
  • Page 13: Printers

    Printers for 16700B/ 16702B (Your printer) Target Target Keyboard Mouse To 16701 Expansion Frame To 16701 Expansion Frame Control Control 16700B or 16702B 16allp13...
  • Page 14 Printers for 16700B/ 16702B (Your printer) Refer to “ Network Printer Setup” in online help for networked printers. Printer Setup Done Done 16allp14...
  • Page 15: External Disk Drive

    External Disk Drive for 16700A/ 16700B/ 16702A/ 16702B as External Data Drive (Option 008) Removable Drive Set the External Disk drive address to 3 or 4. Power Cable (68 pin) External Disk Drive Termination Plug Cable (68 pin) (50 pin)
  • Page 16 External Disk Drive for 16700A/ 16700B/ 16702A/ 16702B as External Data Drive (Option 008) To power up the system..16700A Logic Analysis System Power Busy Disk Drive Power System power Monitor Power (If applicable) 16700A/B or 16702A/B To power down the system..
  • Page 17 External Disk Drive for 16700B/ 16702B as Removable Boot Drive (Option 009) Removable Drive Set the External Disk Drive address to 6. Power Cable (68 pin) External Disk Drive Termination Plug Cable (68 pin) (50 pin) 16700B or 16702B Target...
  • Page 18 External Disk Drive for 16700B/ 16702B as Removable Boot Drive (Option 009) To power up the system..16700A Logic Analysis System Power Busy Disk Drive Power System power Monitor Power (If applicable) 16700B or 16702B To power down the system..
  • Page 19: External Disk Drive & Cd-Rom Drive

    External Disk Drive & CD-ROM for 16700B/ 16702B A CD-ROM drive and an external hard drive(s) may be connected to the SCSI-II port at the same time. Termination Plug (68 pin) (68 pin) External Disk Drive (68 pin) External Hard Drive...
  • Page 20 External Disk Drive & CD-ROM for 16700B/ 16702B When a system is shipped, the factory installs the current operating system and ordered processor support packages and tools. External Disk Drive Power CD-ROM Drive Power 16700B System power Monitor Power (If applicable)
  • Page 21: Software Installation

    Software Installation for 16700B/ 16702B/ Measurement Modules When a system is shipped, the factory installs the current operating system and ordered processor support packages and tools. 16allp17...
  • Page 22 Software Installation for 16700B/ 16702B/ Measurement Modules Select Media Type Additional Tools AUXILIARY-SW HP1670X PROC-SUPPORT System Software Processor Support 167XXB Install 16allp18...
  • Page 23 Software Installation for 16700B/ 16702B/ Measurement Modules AUXILIARY-SW HP 1670X PROC-SUPPORT (Selected Package) (Selected Package) Select desired package or packages. (Selected Package) (Selected Package) The system will automatically reboot if it Install is required by the newly installed package. Software Installation...
  • Page 24: 16701A/B Expander Frame

    16701A/B Expander Frame for 16700B/ 16702B/ Measurement Modules 16700B or 16702B Install your measurement modules in the 16701A/B expander frame. Connect the desired length Target Target Keyboard Mouse To 16701 Expansion Frame To 16701 Expansion Frame Control Control interconnect cable and tighten the connector screws with the screw driver provided.
  • Page 25: Probing

    Probing for 16700B/ 16702B/ Measurement Modules General-Purpose Probing Logic Analyzer Ground Lead Ground Lead (Short) (Long) Probe Tip Probe Tip Assembly Assembly 01650-61608 01650-61608 Probe Housing Probe Tip Probe Lead General-purpose probing requires connecting probe leads to individual signal lines. It is generally the most cumbersome method, but it is also the most flexible.
  • Page 26 Probing for 16700B/ 16702B/ Measurement Modules General-Purpose Probing The signal and ground leads can be connected directly to the target system. This requires installing 0.63 mm (0.025 inch) square pins, or round pins with a diameter between 0.66 and 0.84 mm (0.026 and 0.033 inch) directly on the board. You can also use an IC test clip with pins with those dimensions.
  • Page 27 Probing for 16700B/ 16702B/ Measurement Modules Termination Adapter The logic analyzer cable must have the proper RC network at its input in order to acquire data correctly. The optional Termination Adapter incorporates the RC network into a convenient package. It also reduces the number of pins required for the header on the target board from 40 pins to 20.
  • Page 28 (earth) grounds and not "floating" grounds. All the lines are woven into a flat ribbon that is 4.5 feet long. For more information, contact your Agilent Technologies Sales office and ask for the Application Note: Probing Solutions for Agilent Logic Analysis Systems.
  • Page 29 Probing for 16700B/ 16702B/ Measurement Modules High Density Adapter E5346A (With Tip RC Network) The E5346A high-density adapter provides a convenient and easy way to connect an Agilent logic analyzer to the signals on your target system for packages that are difficult to probe, such as BGAs.
  • Page 30 Probing for 16700B/ 16702B/ Measurement Modules High Density Adapter E5351A (No Tip Network) The E5351A high-density adapter provides a convenient and easy way to connect an Agilent logic analyzer to the signals on your target system for packages that are difficult to probe, such as BGAs.
  • Page 31: Self-Test

    Self-Test for 16700B/ 16702B/ all Measurement Modules (Measurement Modules) Choose a module and select the desired test. 16allp26...
  • Page 32: Specifications & Characteristics

    Specifications & Characteristics for 16700B/ 16702B/ all Measurement Modules Select on the Main Menu Select an instrument 16allp28...
  • Page 33: Disaster Recovery

    “Saving System Settings” and “Reloading System Settings" in this section. You will need to connect a keyboard to your 16702B in order to execute disaster recovery procedures. A batch process is used to autoload the software and then reboot the instrument. The batch process waits for only a short timeout period for user interaction to abort the process.
  • Page 34 Disaster Recovery Reinstalling the Operating System. At the prompt: Main Menu: Enter command > Type: BO P1 <Enter> Interact with IPL (Y, N, Q) ?> Type: N <Enter> After about 30 seconds you will see the message: WARNING: The configuration information calls for a non-interactive installation.
  • Page 35: Saving System Settings

    Saving System Settings By saving your system settings to a flexible disk or a mounted directory, you create a backup file that can be used to quickly setup systems, or restore current system settings after the Disaster Recovery procedure. disas...
  • Page 36: Reloading System Settings

    Reloading System Settings If an item is not valid, or was not initially saved to the file, the selection will be greyed out in the interface. Also, if no file extension is added, a “set” extension is automatically added for you. disasbk...
  • Page 37: Multiframe

    Multiframe for 16700B/ 16702B As many as eight 16700B’s and/or 16702B’s with Agilent 16700-68717 multiframe modules installed may be connected together. The frame at the beginning of the series must have its INPUT port open and the last frame in the series must have its port open.
  • Page 38 Multiframe for 16700B/ 16702B Install the Multiframe Modules into 16700B or 16702B frames. CAUTION Be sure to unplug the power cable before beginning this procedure. 16allp39...
  • Page 39 Multiframe for 16700B/ 16702B Multiframe Module 16allp40...
  • Page 40: Proper Cleaning

    Proper Cleaning for 16700B/ 16702B/ all Measurement Modules Instrument Cabinet and Module Front Panels CAUTION With the instrument unplugged, use mild soap and water to clean the cabinet of the instrument or the front of the modules. Harsh soap might damage the water-based paint.
  • Page 41: 16517/18A

    Measurement Modules 16533/34A 16517/18A 16522A 16533/34A 16557D 16720A 16710/11/12A 16715/16/17/18/19A 16720A 16750/51/52A 16557D 16522A 16710/11/12A 16715/ 16/17/18/19A 16517/18A for 16700A/B 16702A/B 16701A/B 16allp21...
  • Page 42: General Installations

    Measurement Modules General Installation CAUTION Be sure the frame is unplugged before removing or installing modules. Power Busy Power down Disconnect the the system. power cable. Insert modules or filler panels. modules Remove or filler panels. (Other modules filler panels.) modules (Other filler panels.)
  • Page 43 16517A/18A 2-Card Module Expander Master 2 Connector Cable (16518A) (16517A) Master Expander 2 Connector Cable (16517A) (16518A) 16517p08...
  • Page 44 16517A/18A 3-Card Module Master Expander Expander 3 Connector Cable (16517A) (16518A) (16518A) 16517p07...
  • Page 45 16517A/18A 3-Card Module 2 Connector Cable Expander Master Expander 2 Connector Cable (16518A) (16517A) (16518A) 16517p06...
  • Page 46 16517A/18A 3-Card Module Expander Expander Master 3 Connector Cable (16518A) (16518A) (16517A) 16517p05...
  • Page 47 16517A/18A 4-Card Module 2 Connector Cable Expander Master Expander Expander 3 Connector Cable (16518A) (16517A) (16518A) (16518A) 16517p04...
  • Page 48 16517A/18A 4-Card Module Expander Expander Master Expander 3 Connector Cable 2 Connector Cable (16518A) (16518A) (16517A) (16518A) 16517p03...
  • Page 49 16517A/18A 5-Card Module Expander Expander Master Expander Expander 3 Connector Cables (Need 2) (16518A) (16518A) (16517A) (16518A) (16518A) 16517/18 Done Done 16517p02...
  • Page 50: 16522A

    16522A Single-Card Module 2x10 cable connection for a single-card Each 16522A shipped stand alone has 2x10 cable connected in the single-card module configuration. 2x10 cable Master A single-card module configuration can be installed in any available slot. Be sure the frame is unplugged before CAUTION removing or installing modules.
  • Page 51 16522A 2-Card Module 2x10 Cable Expander Master 3-Card Module 2x10 Cable Expander Master Expander 16522p03...
  • Page 52 16522A 4-Card Module Carefully slide the four cards half way into the mainframe slots. Cable the bottom Expander to the Master Card first. Cable the upper two Expanders to the Master Card. Gently slide the cabled assembly fully into the frame and tighten.
  • Page 53 16522A 5-Card Module Carefully slide the five cards half way into the mainframe slots. Cable the bottom two Expanders to the Master first. Cable the upper two Expanders to the Master. Gently slide the cabled assembly fully into the frame and tighten.
  • Page 54: 16533/34A

    16533/34A Calibration Single-Card Module 16600A Series Power down the mainframe. 16700A/B Remove the module from the mainframe and set the PROTECTED / UNPROTECTED 16702A/B switch to UNPROTECTED. UNPROTECTED PROTECTED If you calibrate this module without unprotecting the memory, the new calibration settings will not be saved when the system is shut down.
  • Page 55 16533/34A Calibration Single-Card Module Target Target Out - Port - In Out - Port - In Keyboard Keyboard Mouse Mouse Control Control SCSI-2 Single Ended SCSI-2 Single Ended 10Base-T 10Base-T RS 232 RS 232 Monitor Monitor Parallel Printer Parallel Printer 10Base2 10Base2 Target...
  • Page 56 16533/34A Calibration Single-Card Module For more accurate calibration, allow the system 30 minutes to warm up. Connect the BNC Tee and the (equal length) BNC cables to the module. 16533p03...
  • Page 57 16533/34A Calibration Single-Card Module Select - > 16534A 16533p04...
  • Page 58 16533/34A Calibration Single-Card Module 16533p05...
  • Page 59 16533/34A Calibration Single-Card Module Connect the BNC Tee, adapter, and the (equal length) BNC cables to the module. 16533p06...
  • Page 60 16533/34A Calibration Single-Card Module Remember to set the PROTECTED/UNPROTECTED switch back to PROTECTED. If you just calibrated this card as one of a multi-card set, you must leave the PROTECTED/UNPROTECTED switch in the UNPROTECTED position until you have completed the multi-card calibration procedure on the following pages.
  • Page 61 (See previous pages: 16533/34A Single-Card Module The following example is of a two board arrangement. Up to four cards may be configured in a 16700A, 16700B, 16702A, or 16702B mainframe. Master Connect the module cables. Exit the current session and restart.
  • Page 62 16533/34A Calibration Multi-Card Module Select - > 16534A Connect the (equal length) BNC calibration between channel 1, AC/DC cal, and channel 1 of the second card. (Channel 1 of the third card next time etc. up to four cards.) Chan. 1 Chan.
  • Page 63 16533/34A Calibration Multi-Card Module Repeat steps 3 through 7 for each additional card in your multi-card module. Select the appropriate combination for each additional card. Remember to set the PROTECTED/UNPROTECTED switch back to PROTECTED. Multi-Module Calibration Done Done 16533p10...
  • Page 64: 16557D

    16557D Single-Card Module 2x10 Cable When ordered as a single card, the 16557D is shipped with the 2x10 cable factory configured as a single card module. 2x10 Cable Master 16557p03...
  • Page 65 16557D 2-Card Module Find the required two connector 2x25 cables and connect the cables as shown. 2x25 Cables (Need 2) Expander Master Connect the 2x10 cables on the Expander to the Master. 2x10 Cables Expander Master 16557p04...
  • Page 66 16557D 3-Card Module Find the required three connector 2x25 cables and connect the cables as shown. 2x25 Cables (Need 2) Expander Master Expander Connect the 2x10 cables on the Expanders to the Master. 2x10 Cables Expander Master Expander 16557p05...
  • Page 67 16557D 4-Card Module Find the required four connector 2x25 cables and connect the cables as shown. 2x25 Cables (Need 2) Expander Expander Master Connect the 2x10 cables on the Expanders to the Master. Expander 2x10 Cables Expander Expander Master Expander 16557p06...
  • Page 68 16557D 5-Card Module Find the required five connector 2x25 cables and connect the cables as shown. 2x25 Cables (Need 2) Expander Expander Master Connect the 2x10 cables on the Expanders to the Master. Expander 2x10 Cables Expander Expander Expander Master Expander Expander 16557p07...
  • Page 69: 16710/11/12A

    16710/ 11/ 12A Single-Card Module The 16700A, 16700B, 16702A and 16702B require Rev. A.01.20.00 or higher. See the Software Installation chapter in the book. Select 1660X-70XA. A single 16710A, 16711A, and 16712A will have the 2x40 cable connected in the single-card configuration.
  • Page 70 16710/ 11/ 12A Multi-Card Module 2x40 Cable Master 2x25 Cable 2x25 Cable Expander 2x40 Cable 16710P03...
  • Page 71 16710/ 11/ 12A Multi-Card Module Other modules or filler panels. Multi-Card Module Done Done 16710P04...
  • Page 72: 16715-19A /50-52A

    16715/ 16/ 17/ 18/ 19A 16750/ 51/ 52A Single-Card Module A single 16715/ 16/ 17/ 18/ 19A or 16750/ 51/ 52A will have the 2x40 cable connected in the single-card configuration. 2x10 Cable Master 16715/ 16/ 17A's require software Rev. A.01.40.00 or higher The 16718/ 19A's require software Rev.
  • Page 73 16715/ 16/ 17/ 18/ 19A 16750/ 51/ 52A 2-Card Module 2x10 Cable Connect the 2x10 cable of the Expander to the Master. Expander Master 2x40 Cable Open the accessory pouch and find two of the required 2x40 cables . Connect 2x40 cables on the modules as shown.
  • Page 74 16715/ 16/ 17/ 18/ 19A 16750/ 51/ 52A 3-Card Module Connect the 2x10 cables of the Expanders to the Master. Find the 2x40 cables in the accessory pouch and connect them between the modules. 2x10 Cable Expander 2x40 Cable Master 2x40 Cable 2x40 Cable...
  • Page 75 16715/ 16/ 17/ 18/ 19A 16750/ 51/ 52A 4-Card Module Connect the 2x10 cables of the Expanders to the Master. Find the 2x40 cables in the accessory pouch and connect them between the modules. 2x10 Cables Expander 2x40 Cable Expander 2x40 Cable 2x40 Cable...
  • Page 76 16715/ 16/ 17/ 18/ 19A 16750/ 51/ 52A 5-Card Module Connect the 2x10 cables of the Expanders to the Master. Find the 2x40 cables in the accessory pouch and connect them between the modules. 2x10 Cables Expander 2x40 Cable Expander 2x40 Cable 2x40 Cable...
  • Page 77: 16720A

    16720A Single-Card Module 2x10 cable connection for a single-card Each 16720A shipped stand alone has 2x10 cable connected in the single-card module configuration. 2x10 cable Master A single-card module configuration can be installed in any available slot. Be sure the frame is unplugged before CAUTION removing or installing modules.
  • Page 78 16720A 2-Card Module 2x10 Cable Expander Master 3-Card Module 2x10 Cable Expander Master Expander 16720p03...
  • Page 79 16720A 4-Card Module Carefully slide the four cards half way into the mainframe slots. Cable the bottom Expander to the Master Card first. Cable the upper two Expanders to the Master Card. Gently slide the cabled assembly fully into the frame and tighten.
  • Page 80 16720A 5-Card Module Carefully slide the five cards half way into the mainframe slots. Cable the bottom two Expanders to the Master first. Cable the upper two Expanders to the Master. Gently slide the cabled assembly fully into the frame and tighten.
  • Page 81 EMC Directive 89/336/EEC (including 93/68/EEC) and carries the CE marking accordingly. (European Union) *This product was tested in a typical configuration with Agilent Technologies test systems. Date: 11/18/99 Ken Wyatt / Product Regulations Manager For further information, please contact your local Agilent Technologies sales office, agent, or distributor. dconframes...
  • Page 82 Installation category (overvoltage category) Signal level, special equipment or parts of Definitions equipment, telecommunication, electronic etc., with smaller transient overvoltages than installation (overvoltage category) Installation category (overvoltage category) Local level, appliances, portable equipment etc., with smaller transient overvoltages than installation category III.
  • Page 83 EMC Directive 89/336/EEC, and carries the CE marking accordingly. This product was tested in a typical configuration with Agilent Technologies test systems. Colorado Springs, 10/03/96 Ken Wyatt / Product Regulations Manager For further information, please contact your local Agilent Technologies sales office, agent, or distributor. dconoldmods...
  • Page 84 Definitions Installation category (overvoltage category) Signal level, special equipment or parts of equipment, telecommunication, electronic etc., with smaller transient overvoltages than installation (overvoltage category) Installation category (overvoltage category) Local level, appliances, portable equipment etc., with smaller transient overvoltages than installation category III.
  • Page 85 EMC Directive 89/336/EEC (including 93/68/EEC) and carries the CE marking accordingly. (European Union) *This product was tested in a typical configuration with Agilent Technologies test systems. Date: 02/08/2000 Ken Wyatt / Product Regulations Manager For further information, please contact your local Agilent Technologies sales office, agent, or distributor. dconnewmods...
  • Page 86 Definitions Installation category (overvoltage category) Signal level, special equipment or parts of equipment, telecommunication, electronic etc., with smaller transient overvoltages than installation (overvoltage category) Installation category (overvoltage category) Local level, appliances, portable equipment etc., with smaller transient overvoltages than installation category III.
  • Page 87 Copyright Safety Safety Symbols Agilent Technologies Inc. 2000 Service instructions are for This apparatus has been designed All Rights Reserved. and tested in accordance with IEC trained service personnel. To avoid dangerous electric shock, Publication 1010, Safety Reproduction, adaptation, or...
  • Page 88 Technologies from another country. specifications at the time of shipment from the factory. Agilent Agilent Technologies warrants that Technologies Inc. further certifies its software and firmware that its calibration measurements designated by Agilent Technologies...

This manual is also suitable for: