Error Messages - Gerber MAXX 2 Owner's Manual

Wide-format thermal printer
Table of Contents

Advertisement

46
CHAPTER 7
Understanding Messages

Error Messages

When system errors are detected during the MAXX 2 operation, the "Error(s) Detected"
message is displayed. The exact error or errors can be viewed on the MAXX 2 display by
pressing the appropriate function key on the keypad. Clear the message after viewing by
pressing the ENTER key.
The errors, their meanings, and suggested actions are listed in the table below.
Error message
Button Version Read
Error 1
Button Version Read
Error 2
Button Write Error 1
Button Write Error 2
Can't Open Boost
File
Can't Open Config
File
Can't Open Job File
Can't Open Knobs
File
Can't Open
Language File
Can't Open Network
File
Can't Open 50%
Compensation File
Can't Open 75%
Compensation File
Check Vacuum
Muffler
Data Expansion
Error
Meaning
The foil button version field can not be
read.
The foil button version field can not be
read.
The foil button version number field in
memory is corrupt.
The foil button version number field in
memory is corrupt.
This error may indicate a disk corruption
problem.
This error may indicate a disk corruption
problem.
This error may indicate a disk corruption
problem.
The knobs configuration file that stores
calibration and setup data is corrupt or
missing.
The language configuration file(s) is
corrupt or missing.
The network configuration file can't be
opened.
The currently selected 50% density
compensation file can't be opened.
The currently selected 75% density
compensation file can't be opened
The measured vacuum is more than 25
counts above the calibrated vacuum
threshold.
Compressed stored image data is not
expanded correctly.
Action
Check the contacts on the cassettes and
bays. Change the foil in the cassette.
Check the contacts on the cassettes and
bays. Change the foil in the cassette.
The button will not be updated when
the cassette is unloaded from the
carriage. Check the contacts on the
cassettes and bays. Change the foil in
the cassette.
The button will not be updated when
the cassette is unloaded from the
carriage. Check the contacts on the
cassettes and bays. Change the foil in
the cassette.
Contact Gerber Field Service.
Contact Gerber Field Service.
Contact Gerber Field Service.
Contact Gerber Field Service.
Contact Gerber Field Service.
Contact Gerber Field Service.
Contact Gerber Field Service.
Contact Gerber Field Service.
Clean the vacuum muffler. If error still
occurs, contact Gerber Field Service.
Re-render the job and re-send it to the
printer.

Advertisement

Table of Contents
loading

This manual is also suitable for:

2

Table of Contents