Error message
Meaning
Time Out Waiting
PC fails to receive notification of the
For X Stop
X-axis stop in a reasonable amount of
time.
Time Out Waiting
PC fails to receive notification of the
For Y Stop
Y-axis stop in a reasonable amount of
time.
Time Out Waiting for
PC fails to receive notification of the
Z Stop
Z-axis stop in a reasonable amount of
time.
Time Out Waiting To
PC has not received acknowledgement
Send Line Data
of previous command when waiting to
send print data.
Too Many Lines in
Swipe contains more than 10200 lines
Swipe
of data. The job is aborted.
Vacuum System
Measured vacuum is less than the
Fault
configured vacuum threshold.
Workspace Error 1
A firmware error in which the
workspace allocated for the PC
operating system has overflowed.
X-axis Left Encoder
The X-axis has synched out and lost
Error
position.
X-axis Left Home
The X-axis has synched out and lost
Error
position.
X-axis Right Encoder
The X-axis has synched out and lost
Error
position.
X-axis Right Home
The X-axis has synched out and lost
Error
position.
Y Axis Max Limit
The Y-axis limit was reached during the
Reached During Job
job
Action
Cycle power. If error continues, contact
Gerber Field Service.
Cycle power. If error continues, contact
Gerber Field Service.
Cycle power. If error continues, contact
Gerber Field Service.
Cycle power. If error continues, contact
Gerber Field Service.
Re-render the job and re-send it to the
printer.
Check the vacuum threshold and adjust
if needed. If error continues, contact
Gerber Field Service.
Cycle power. If error continues, contact
Gerber Field Service.
Contact Gerber Field Service.
Contact Gerber Field Service.
Contact Gerber Field Service.
Contact Gerber Field Service.
Contact Gerber Field Service.
49