ERROR CODE
E061
Description
xx30 The measurement of VD1 is 400 V or higher.
xx31 The measurement of VD1 is 200 V or lower.
xx32 The measurement of VD2 is 800 V or higher.
xx33 The measurement of VD2 is 500 V or lower.
xx34 The measurement of VL1 is 200 V or higher.
xx35 The measurement of VL2 is 400 V or more.
xx36 The measurement of VL2 is 0 V or lower.
Cause
• Potential measurement unit (faulty)
• DC controller PCB (faulty)
Description
xx50 The difference between the computation value of Vdc measured
xx51 The difference between the computation value of Vg measured pre-
Cause
• Potential measurement unit (faulty)
• HVDC (faulty)
• Video controller PCB (faulty)
• Laser unit (faulty)
• Laser shutter (faulty)
• Scanner (faulty)
• Environment sensor (faulty)
• Photosensitive drum (faulty)
• Photosensitive drum (poor grounding)
Description
xx52 The computation value of V00 is the upper limit value (325 V) or
xx53 The computation value of V00 is the lower limit value (325 V) or
E-14
previously and the computation value of Vdc measured currently is
30 V or more.
viously and the computation value of Vg measured currently is 30
V or more.
higher.
lower.