DISP
COUNTER
ADJUST
FUNC
OPTION
TEST
BODY °C
Indicates the machine internal temperature measured by the environment
sensor.
Remarks
Same as the reading under 'DISPLAY > ANALOG'
BODY %
Indicates the machine internal humidity measured by the environment sensor.
Remarks
Same as the reading under 'DISPLAY > ANALOG'
BODY g
Indicates the machine internal humidity absolute value (g) measured by the
environment sensor.
Remarks
Same as the reading under 'DISPLAY > ANALOG'
<<<ZONE-A>>>
Indicates the zone in which the setting shown is effective.
EL-N1
Effective in plain paper mode and, in addition, when copying on a one-
sided copy or on the 1st side of a two-sided copy.
Settings range –5 ~ +1 (Standard: -2)
Unit: 0.5 kV
EL-N2
Effective in plain paper mode and, in addition, when copying on the 2nd
side of a two-sided copy.
Settings range –5 ~ +1 (Standard: -2)
Unit: 0.5 kV
EL-OHP
Effective in OHP mode.
Settings range –5 ~ +1 (Standard: -2)
Unit: 0.5 kV
COPYRIGHT © 2001 CANON INC.
<M>
<S>
HV-EL
2/4
BODY
xxx
˚C
BODY
xxx
%
BODY
xxx
g
<<<<<<< ZONE A >>>>>>>
EL-N1
EL-OHP
xxxx
xxxx
EL-N2
EL-#
xxxx
xxxx
F00-300-32
2000 2000 2000 2000
<R>
EL-T1
EL-S1-2
xxxx
EL-T2
EL-S2-1
xxxx
EL-UT1
EL-S2-2
xxxx
EL-UT2
EL-S3-1
xxxx
EL-S1-1
EL-S3-2
xxxx
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
<P>
<F>
xxxx
xxxx
xxxx
xxxx
xxxx
S-75