Detecting Low Temperature Of Oil (Software); Detecting Low Temperature Of Oil (Hardware); Operation Of The Thermal Switch - Canon CLC5000 Service Manual

Hide thumbs Also See for CLC5000:
Table of Contents

Advertisement

6.6.7 Detecting Low Temperature of Oil (software)

The CPU on the DC controller PCB monitors the voltage of the oil thermistor (TH5) and
the oil heater thermistor (TH6), and the DC control PCB will issue the following error codes
in the presence of a fault and then cause the power OFF signal (PWOFF*) to go '0', thereby
turning off the power switch (SW2):
Thermistor
Oil thermistor (TH5)
Oil heater thermistor (TH6)

6.6.8 Detecting Low Temperature of Oil (hardware)

If the low temperature detention circuit on the DC controller PCB doesn't detect 50ºC
within 2 min after the oil heater turns on the following error code will be issued:
Thermistor
Oil heater thermistor (TH6)

6.6.9 Operation of the Thermal Switch

If the temperature inside the thermal switch of the upper fixing heater, lower fixing heater,
or oil heater exceeds 230ºC, the respective switch turns off to cut off the power to its heater.
The contact of the thermal switch (TP1, TP2, TP3) will not recover even
when the temperature returns to normal. Do not use it once its contact has
REF.
opened.
Resetting E000
1) Remove the cause.
2) Start service mode, and make the following selections:
FUNCTION>USER.
3) Press 'E000-RLS' so that the <P> notation will change as follows: ER-
ROR
4) Turn off and then on the power switch.
COPYRIGHT © 2001 CANON INC.
Condition
It does not reach 50ºC after the end
of WAIT.
It does not reach 50ºC after the end
of WAIT.
Error code
E000-0082
BUSY
ERROR.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
CHAPTER 2 NEW FUNCTIONS
Error code
E000-0062
E000-0072
2-129

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fy8-13gz-000

Table of Contents