Canon CLC5000 Service Manual page 272

Hide thumbs Also See for CLC5000:
Table of Contents

Advertisement

4) Pull the retaining handle to the from,
and push up the retainer unit; then, re-
move the three screws [4], and detach
the lower arm base [5] and then the
pressure plate [6].
6) Remove the E-ring [7], washer [8], and
bearing [9] at the front and the rear;
then, detach the curl removing roller.
When removing the lower arm
base, be sure to support the
pressure plate with your hand. If
you pull off the lower arm base
without support, the pressure
plate can fall. Be sure to take
care.
In addition, do NOT remove the
screw [A] in detected in the fig-
ure.
COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
CHAPTER 2 NEW FUNCTIONS
[5]
[4]
[4]
F02-907-09
[10]
[9]
[8]
[7]
F02-907-10
[A]
F02-907-11
[6]
[7]
[8]
[9]
Pressure plate