Canon CLC5000 Service Manual page 729

Hide thumbs Also See for CLC5000:
Table of Contents

Advertisement

ERROR CODE
Cause
The oil heater thermistor or the oil thermistor has a short circuit; the AC
driver PCB is faulty; or the DC controller PCB is faulty.
Description
0061 The oil thermistor has detected overheating (180°C).
0071 The oil thermistor has detected overheating (220°C).
0081 The high-temperature detection circuit on the DC controller PCB
Cause
The oil heater thermistor or the oil thermistor has an open circuit; the AC
driver PCB is faulty; or the DC controller PCB is faulty.
Description
0062 At the end of the WAIT period, the output of the oil thermistor
0072 At the end of the WAIT period, the oil heater thermistor does not
0082 The output of the oil heater thermistor does not reach 50ºC within
E004
Cause
Triac (short circuit)
Description
0001 The triac is ON after the CPU on the DC controller PCB has turned
0002 The triac is ON after the CPU on the DC controller PCB has turned
E005
Cause
• Cleaning web (inside fixing assembly; taken up)
• Web length sensor (PS36; faulty)
• DC controller PCB (faulty)
Description
The cleaning web solenoid has turned ON 270 times after the web length
sensor detected the lever.
E-2
has detected overheating (190°C for the oil thermistor output;
230°C for the oil heater thermistor).
does not reach 50°C.
reach 50°C.
2min after the oil heater has gone ON; as detedted by the low-
temperature detection circuit on the DC controller PCB (after the
oil temperature has reached a specific level).
ON the fixing heater triac drive signal.
OFF the triac drive signal for the drum heater.
COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fy8-13gz-000

Table of Contents