CHAPTER 5 TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS

4.1.4 E008

Fixing oil
1) Does the oil case have an adequate amount of fixing oil?
NO:
Fixing oil supply route
2) Is the hose from the oil case to the upper oil pan clogged with dust?
YES: Remove the clogging; or, replace the part.
Fixing oil level detect sensor (PS6)
3) Is the fixing oil level detect sensor (PS6) normal? (Check as when
NO:
Fixing oil pump drive solenoid (SL2)
4) Operate the fixing oil pump drive solenoid using 'IO-ON' of
NO:
DC controller PCB
5) Operate the solenoid using 'IO-ON' of 'FMISCp' under 'FUNC' in
NO:
5-110
Supply oil.
checking a photointerrupter.)
Check the wiring from the DC controller PCB to the sensor; if nor-
mal, replace the fixing oil level detect sensor (PS6).
'FMISCp' under 'FUNC' in service mode. Does it operate nor-
mally?
Check the wiring from the DC controller PCB to the fixing oil
pump drive solenoid; if normal, replace the fixing oil pump drive
solenoid.
service mode. At this time, does the voltage between J2209A-4 and
J2209A-5 on the DC controller PCB change from 24 V to 0 V?
Replace the DC controller PCB.
COPYRIGHT © 2001 CANON INC.