5) Free the harness of the transfer cleaner
motor [6] from the clamp [7], and dis-
connect the connector [8].
6) Move the transfer cleaner unit [3] to the
left to detach.
7) Open the transfer belt assembly. (See
the instructions on how to open the
transfer belt.)
8) Loosen the mounting screw [9] to free
the sensor unit fixing plate [10].
COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
CHAPTER 2 NEW FUNCTIONS
[7]
[8]
[6]
F02-405-54
[3]
F02-405-55
[9]
F02-405-56
[10]
2-73