CHAPTER 2 NEW FUNCTIONS

5.7.7 Removing the Duplex Unit Feed roller

1) Remove the duplex unit.
2) Remove the two resin clamps [1], and
detach the feed roller [3] from the feed
roller shaft [2].

5.7.8 Removing the Pre-Fixing Feeding Assembly

1) Remove the left cover.
2) Slide out the fixing unit and the transfer
unit.
3) Remove the two screws [1].
2-112
COPYRIGHT © 2001 CANON INC.
[3]
[1]
[2]
F02-507-14