Canon CLC5000 Service Manual page 739

Hide thumbs Also See for CLC5000:
Table of Contents

Advertisement

ERROR CODE
E061
Cause
• Primary charging assembly (faulty)
• HVDC (faulty)
Description
xx11 The measurement of VD1 is 900 V or higher and, in addition, the
Cause
• Video controller PCB (faulty)
• Laser unit (faulty)
Description
xx12 The measurement of VD1 is 200 V or lower and, in addition, the
xx13 The measurement of VD1 is 150 V or lower and, in addition, the
Cause
• Primary charging assembly (faulty)
• HVDC (faulty)
Description
xx14 The measurement of VD1 is 150 V or lower and, in addition, the
Cause
• Potential measurement unit (faulty)
• DC controller PCB (faulty)
Description
xx15 The measurement of VD1, VD2, VL1, or VL2 is 10 V or lower.
Cause
• Video controller PCB (faulty)
• Laser unit (faulty)
• Scanner (faulty)
Description
xx16 The difference between VD1 and VL1 measurements is 20 V or
Cause
• Video controller PCB (faulty)
• Laser intensity (poor adjustment)
• Laser unit (faulty)
Description
xx17 The VL1 measurement is 200 V or higher and, in addition, the VL2
E-12
measurement of VD2 is 900 V or higher.
measurement of VD2 is 600 V or lower.
measurement of VD2 is 300 V or lower.
measurement of VD2 is 150 v or lower.
less and, in addition, the measurement of VD1 is 200 V or more.
The difference between VD2 and VL2 measurements is 200 V or
less and, in addition, the VD2 measurement is 600 V or higher.
measurement is 400 V or higher.
COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fy8-13gz-000

Table of Contents