CHAPTER 3 INSTALLATION
Step
10
Remove the four primary charging
assemblies.
After removal, place each pri-
mary charging assembly so that
its grid side faces up.
11
Remove the four photosensitive drum
positioning knobs.
The knobs have a two-layer construc-
tion. To remove, turn the small knob at
the center counterclockwise.
12
Remove the two screws from the process
unit mount.
3-16
Work
COPYRIGHT © 2001 CANON INC.
Remarks
Primary charging
assembly
F03-303-06
Positioning knob
F03-303-07
Screw
Process unit mount Screw
F03-303-08
2000 2000 2000 2000