Configuring Overlay Vsans - HP Cisco MDS 9020 - Fabric Switch Configuration Manual

Cisco mds 9000 family cli configuration guide, release 3.x (ol-16184-01, april 2008)
Hide thumbs Also See for Cisco MDS 9020 - Fabric Switch:
Table of Contents

Advertisement

Chapter 43
Configuring IP Services
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m

Configuring Overlay VSANs

To configure an overlay VSAN, follow these steps:
Add the VSAN to the VSAN database on all switch in the fabric.
Step 1
Create a VSAN interface for the VSAN on all switches in the fabric. Any VSAN interface belonging to
Step 2
the VSAN has an IP address in the same subnet. Create a route to the IPFC cloud on the IP side.
Configure a default route on every switch in the Fibre Channel fabric pointing to the switch that provides
Step 3
NMS access.
Configure the default gateway (route) and the IPv4 address on switches that point to the NMS (see
Step 4
Figure
Figure 43-4
To configure the management interface displayed in
Note
address on the Ethernet network.
The following procedure configures an overlay VSAN in one switch. This procedure must be repeated
for each switch in the fabric.
OL-16184-01, Cisco MDS SAN-OS Release 3.x
43-4).
Overlay VSAN Configuration Example
Int vsan10 - 10.10.10.88
VSAN HR
Int vsan10 - 10.10.10.124
IP default gateway
10.10.10.34
VSAN 10
Int vsan10 - 10.10.10.35
Int vsan10 - 10.10.10.34
VSAN ENG
172.23.84.74
mgmt 0
172.23.84.86
NMS
IP cloud
ip route 10.10.10.0 255.255.255.0 172.23.93.74
Physical Fibre
Channel Fabric
Figure
43-4, set the default gateway to an IPv4
Cisco MDS 9000 Family CLI Configuration Guide
Overlay VSANs
43-13

Advertisement

Table of Contents
loading

Table of Contents