On-Board Failure Logging - HP Cisco MDS 9020 - Fabric Switch Configuration Manual

Cisco mds 9000 family cli configuration guide, release 3.x (ol-16184-01, april 2008)
Hide thumbs Also See for Cisco MDS 9020 - Fabric Switch:
Table of Contents

Advertisement

On-Board Failure Logging

S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Example 59-24 Displays Loopback Test Statistics for the Entire Switch
switch# show system health statistics loopback
-----------------------------------------------------------------
Mod Port Status
1
3
8
-----------------------------------------------------------------
Example 59-25 Displays Loopback Test Statistics for a Specified Interface
switch# show system health statistics loopback interface fc 3/1
-----------------------------------------------------------------
Mod Port Status
3
-----------------------------------------------------------------
Note
Example 59-26 Displays the Loopback Test Time Log for All Modules
switch# show system health statistics loopback timelog
-----------------------------------------------------------------
Mod
1
3
8
-----------------------------------------------------------------
Example 59-27 Displays the Loopback Test Time Log for a Specified Module
switch# show system health statistics loopback module 8 timelog
-----------------------------------------------------------------
Mod
8
-----------------------------------------------------------------
On-Board Failure Logging
The Generation 2 Fibre Channel switching modules provide the facility to log failure data to persistent
storage, which can be retrieved and displayed for analysis. This on-board failure logging (OBFL) feature
stores failure and environmental information in nonvolatile memory on the module. The information will
help in post-mortem analysis of failed cards.
This section includes the following topics:
Cisco MDS 9000 Family CLI Configuration Guide
59-22
16 Running
32 Running
8 Running
1 Running
Interface-specific counters will remain at zero unless the module-specific loopback test reports
errors or failures.
Samples
Min(usecs)
1872
1862
1865
Samples
Min(usecs)
1867
About OBFL, page 59-23
Configuring OBFL for the Switch, page 59-23
Run
Pass
Fail
12953
12953
0
12945
12945
0
12949
12949
0
Run
Pass
Fail
0
0
0
Max(usecs)
149
364
415
743
134
455
Max(usecs)
134
455
Chapter 59
Monitoring System Processes and Logs
CFail Errs
0
0
0
0
0
0
CFail Errs
0
0
Ave(usecs)
222
549
349
Ave(usecs)
349
OL-16184-01, Cisco MDS SAN-OS Release 3.x

Advertisement

Table of Contents
loading

Table of Contents