Drive-Related Options
Use the command in the following table to replace configured drive(s) and start an
automatic rebuild of the drive for the selected controller(s).
Table 96: Replace Configured Drive(s) and Start Automatic Rebuild
Convention
Description
Use the command in the following table to prepare the unconfigured drive(s) for
removal from the selected controller(s).
Table 97: Prepare Unconfigured Drive(s) for Removal
Convention
Description
Use the command in the following table to display the total number of drives attached
to an controller. Drives can be attached directly or through enclosures.
Table 98: Display Number of Drives Attached to an Controller
Convention
Description
Use the command in the following table to display a list of the physical devices
connected to the selected controller(s).
Table 99: Display List of Physical Devices Attached to Controller(s)
Convention
Description
MegaCli –PDReplaceMissing –PhysDrv[E0:S0,E1:S1....]
-ArrayX -RowY -aN
Replaces the configured drives that are identified as missing and then starts
an automatic rebuild.
-Physdrv[E0:S0,...]: Specifies the physical drive enclosure and the
slots for the drives.
MegaCli –PDPrpRmv [-Undo] – PhysDrv[E0:S0,E1:S1....]
-aN|-a0,1,2|-aALL
Prepares unconfigured drive(s) for removal. The firmware spins down this
drive. The drive state is set to unaffiliated, which marks it as offline even
though it is not a part of a configuration.
-Undo: This option undoes this operation. If you select undo, the firmware
marks this drive as unconfigured good.
-Physdrv[E0:S0,...]: Specifies the physical drive enclosure and the
slots for the drives.
MegaCli –PDGetNum –aN|-a0,1,2|-aALL
Displays the total number of drives attached to an controller. Drives can be
attached directly or through enclosures. The return value is the number of
drives.
MegaCli –PDList –aN|-a0,1..|-aAll|
Displays information about all drives and other devices connected to the
selected controller(s). This includes information such as the drive type,
capacity (if a drive), serial number,drive temperature, enclosure position, and
firmware version of the device. For SAS devices, this includes additional
information such as the SAS address of the device. For SAS expanders, this
includes additional information such as the number of drives connected to
the expander.