Set Bbu Properties; Options For Displaying Logs Kept At The Firmware Level; Event Log Management - Lenovo ThinkServer RD330 Software User's Manual

Megaraid sas software user guide
Hide thumbs Also See for ThinkServer RD330:
Table of Contents

Advertisement

Chapter 5: MegaRAID Command Tool
Level
5.11.8

Set BBU Properties

5.12
Options for Displaying
Logs Kept at the Firmware Level
5.12.1

Event Log Management

Table 61: Event Log Management
Convention
MegaCli –AdpEventLogInfo –GetEventlogInfo | –GetEvents {-info -warning -critical
-fatal} | GetSinceShutdown {-info -warning -critical -fatal} | GetSinceReboot {-info
-warning -critical -fatal} | IncludeDeleted {-info -warning -critical -fatal} |
{GetLatest <number> {-info -warning -critical -fatal} } -f <filename> | Clear
-aN|-a0,1,2|-aALL | {GetCCIncon} -f <filename> -LX| -L0,2,5...|-LALL -aN|-a0,1,2|-aALL
Description
Manages event log entries. The following are the settings you can select on a single controller, multiple controllers, or all
controllers:
-GetEventlogInfo: Displays overall event information such as total number of events, newest sequence number, oldest
sequence number, shutdown sequence number, reboot sequence number, and clear sequence number.
-GetEvents: Gets event log entry details. The information shown consists of total number of entries available at firmware
side since the last clear and details of each entries of the error log. Start_entry specifies the initial event log entry when
displaying the log.
-GetSinceShutdown: Displays all of the events since last controller shutdown.
-GetSinceReboot: Displays all of the events since last controller reboot.
-IncludeDeleted: Displays all events, including deleted events.
-GetLatest: Displays the latest number of events, if any exist. The event data will be writtent to the file in reverse order.
-Clear: Clears the event log for the selected controller(s).
-GetCCIncon: Displays the events relating to inconsistent data found during a consistency check.
Page 192
|
Options for Displaying Logs Kept at the Firmware
Use the command in the following table to set the BBU properties on the selected
controller(s) after reading from the file.
Table 60: Set BBU Properties
Convention
Description
Use the commands in this section to select the display settings for the event log and
the BBU terminal log, which are kept at the firmware level.
Use the command in the following table to manage the event entries in the event log
for the selected controller(s).
MegaCli -AdpBbuCmd -SetBbuProperties -f<fileName>
-aN|-a0,1,2|-aALL
Sets the BBU properties on the selected controller(s) after reading from the
file.
The information displays in the following formats:
autoLearnPeriod = 1800Sec
nextLearnTime = 12345678Sec Seconds past 1/1/2000
learnDelayInterval = 24hours - Not greater than 7 days
autoLearnMode = 0 0 – Enabled; 1 - Disabled; 2 – WarnViaEvent.
NOTE: You can change only two of these parameters: learnDelayInterval and
autoLearnMode.
NOTE: If the battery type is IBBU08 then in autoLearnmode the
WarnViaEvent is not supported.