Change The Drive State To Unconfigured Good; Change The Drive State - Lenovo ThinkServer RD330 Software User's Manual

Megaraid sas software user guide
Hide thumbs Also See for ThinkServer RD330:
Table of Contents

Advertisement

MegaRAID SAS Software User Guide
5.15.4
Change the Drive State to
Unconfigured Good
5.15.5

Change the Drive State

Use the command in the following table to change the state of a drive from
Unconfigured-Bad to Unconfigured-Good.
Table 89: Change Drive State to Unconfigured Good
Convention
MegaCli –PDMakeGood -PhysDrv[E0:S0,E1:S1....] |
[-Force] -aN|-a0,1,2|-aALL
Description
Changes the drive state to Unconfigured Good.
-Physdrv[E0:S0,...]: Specifies the physical drive enclosure and the
slots for the drives.
Force: Force the drive to the Unconfigured Good state.
Use the command in the following table to change the drive state, as it relates to hot
spares, and to associate the drive to an enclosure and to a drive group for the selected
controller(s)
.
Table 90: Change Drive State
Convention
MegaCli –PDHSP {–Set [{-Dedicated -ArrayN
|-Array0,1...}] [-EnclAffinity] [-nonRevertible] } |
-Rmv -PhysDrv[E0:S0,E1:S1,...] -aN|-a0,1,2|-aALL
Description
Changes the drive state (as it relates to hot spares) and associates the drive
to an enclosure and virtual drive on a single controller, multiple controllers,
or all controllers:
-Set: Changes the drive state to dedicated hot spare for the enclosure.
-Array0: Dedicates the hot spare to a specific drive group number N.
-EnclAffinity: Associates the hot spare to a selected enclosure.
-Rmv: Changes the drive state to ready (removes the hot spare).
-Physdrv[E0:S0,...]: Specifies the physical drive enclosure and the
slots for the drives.
You can get the list of arrays by using the CLI command "CfgDsply". In the
results of the CfgDsply command, the number associated with "DISK
GROUPS" is the array number.
Chapter 5: MegaRAID Command Tool
|
Drive-Related Options
Page 205