Understanding How Environmental Monitoring Works
module 7:
module 7 power-output-fail: OK
module 7 outlet temperature: 42C
module 7 inlet temperature: 29C
EARL 7 outlet temperature: 45C
EARL 7 inlet temperature: 32C
module 9:
module 9 power-output-fail: OK
module 9 outlet temperature: 41C
module 9 inlet temperature: 36C
EARL 9 outlet temperature: 33C
EARL 9 inlet temperature: N/O

Understanding LED Environmental Indications

The LEDs can indicate two alarm types: major and minor. Major alarms indicate a critical problem that
could lead to the system being shut down. Minor alarms are for informational purposes only, giving you
notice of a problem that could turn critical if corrective action is not taken.
When the system has an alarm (major or minor), that indicates an overtemperature condition, the alarm
is not canceled nor is any action taken (such as module reset or shutdown) for 5 minutes. If the
temperature falls 5°C (41°F) below the alarm threshold during this period, the alarm is canceled.
Table 50-2
Refer to the Catalyst 6500 Series Switch Module Installation Guide for additional information on LEDs,
Note
including the supervisor engine SYSTEM LED.
Table 50-2
Environmental Monitoring for Supervisor Engine and Switching Modules
Component
Supervisor engine temperature sensor
1
exceeds major threshold
Supervisor engine temperature sensor
exceeds minor threshold
Redundant supervisor engine
temperature sensor exceeds major or
minor threshold
Catalyst Supervisor Engine 32 PISA Cisco IOS Software Configuration Guide, Release 12.2ZY
50-12
lists the environmental indicators for the supervisor engine and switching modules.
Alarm
Type
LED Indication
2
Major
STATUS
Minor
STATUS LED
orange
Major
STATUS LED red
Minor
STATUS LED
orange
Chapter 50
Power Management and Environmental Monitoring
Action
3
LED red
Generates syslog message and an SNMP trap.
If there is a redundancy situation, the system
switches to a redundant supervisor engine and the
active supervisor engine shuts down.
If there is no redundancy situation and the
overtemperature condition is not corrected, the
system shuts down after 5 minutes.
Generates syslog message and an SNMP trap.
Monitors the condition.
Generates syslog message and an SNMP trap.
If a major alarm is generated and the
overtemperature condition is not corrected, the
system shuts down after 5 minutes.
Monitors the condition if a minor alarm is generated.