This example shows how to display information about the key system resources:
Router# show platform hardware capacity systems System Resources
PFC operating mode: PFC3BXL
Supervisor redundancy mode: administratively rpr-plus, operationally rpr-plus
Switching Resources: Module
This example shows how to display VLAN information:
Router# show platform hardware capacity vlan VLAN Resources
VLANs: 4094 total, 10 VTP, 0 extended, 0 internal, 4084 free Router#

Determining Sensor Temperature Threshold

The system sensors set off alarms based on different temperature threshold settings. You can determine
the allowed temperatures for the sensors by using the show environment alarm threshold command.
This example shows how to determine sensor temperature thresholds:
Router> show environment alarm threshold
environmental alarm thresholds:
power-supply 1 fan-fail: OK
threshold #1 for power-supply 1 fan-fail:
threshold #1 for power-supply 1 power-output-fail:
threshold #1 for fantray fan operation sensor:
threshold #1 for operating clock count:
threshold #2 for operating clock count:
threshold #1 for operating VTT count:
threshold #2 for operating VTT count:
threshold #1 for VTT 1 OK:
threshold #1 for VTT 2 OK:
threshold #1 for VTT 3 OK:
threshold #1 for clock 1 OK:
threshold #1 for clock 2 OK:
threshold #1 for module 1 power-output-fail:
threshold #1 for module 1 outlet temperature:
threshold #2 for module 1 outlet temperature:
threshold #1 for module 1 inlet temperature:
threshold #2 for module 1 inlet temperature:
threshold #1 for module 1 device-1 temperature:
threshold #2 for module 1 device-1 temperature:
OL-11439-03
5
9
(sensor value != 0) is system minor alarm power-supply 1 power-output-fail: OK
(sensor value != 0) is system minor alarm fantray fan operation sensor: OK
(sensor value != 0) is system minor alarm operating clock count: 2
(sensor value < 2) is system minor alarm
(sensor value < 1) is system major alarm operating VTT count: 3
(sensor value < 3) is system minor alarm
(sensor value < 2) is system major alarm VTT 1 OK: OK
(sensor value != 0) is system minor alarm VTT 2 OK: OK
(sensor value != 0) is system minor alarm VTT 3 OK: OK
(sensor value != 0) is system minor alarm clock 1 OK: OK
(sensor value != 0) is system minor alarm clock 2 OK: OK
(sensor value != 0) is system minor alarm module 1 power-output-fail: OK
(sensor value != 0) is system major alarm module 1 outlet temperature: 21C
(sensor value > 60) is system minor alarm
(sensor value > 70) is system major alarm module 1 inlet temperature: 25C
(sensor value > 60) is system minor alarm
(sensor value > 70) is system major alarm module 1 device-1 temperature: 30C
(sensor value > 60) is system minor alarm
(sensor value > 70) is system major alarm module 1 device-2 temperature: 29C
Catalyst Supervisor Engine 32 PISA Cisco IOS Software Configuration Guide, Release 12.2ZY
Understanding How Power Management Works
Part number
WS-SUP720-BASE
supervisor
WS-X6548-RJ-45
Series
CEF mode
CEF
CEF256
CEF
50-9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst supervisor engine 32 pisa

Table of Contents