Parameter
patternNumber
maxErrorCount
testIterations
timeout
NOTE: Use the save physicalDiskChannel faultDiagnostics command and the stop
physicalDiskChannel faultDiagnostics command in association with the start
physicalDiskChannel faultDiagnostics command. These commands are needed to save the
diagnostic test results to a file and to stop the diagnostic test.
NOTE: You can stop this command at any time by pressing Ctrl+C.

Start Physical Disk Initialize

This command starts physical disk initialization.
CAUTION: As soon as you enter this command, all user data is erased.
Syntax
start physicalDisk [enclosureID,slotID] initialize
Parameters
Parameter
physicalDisk

Start Physical Disk Reconstruction

This command starts reconstructing a physical disk.
Syntax
start physicalDisk [enclosureID,slotID] reconstruct
Parameters
Parameter
physicalDisk
212
Description
The hexadecimal data pattern you want to use to run the
test.
This number can be any hexadecimal number between
0000 to FFFF.
The number of errors that you want to accept before
terminating the test.
The number of times that you want to repeat the test.
The length of time in minutes that you want to run the test.
Description
Identifies the enclosure and slot where the physical disk
resides. Enclosure ID values are 0 to 99. Slot ID values
are 0 to 31. You must put brackets ([ ]) around the
enclosure ID value and slot ID value.
Description
Identifies the enclosure and slot where the physical disk
resides. Enclosure ID values are 0 to 99. Slot ID values
are 0 to 31. You must put brackets ([ ]) around the
enclosure ID value and slot ID value.