Rising/Falling Event—The mechanism that reports the alarms: LOGed or TRAPed or
a combination of both. When LOG is selected, there is no saving mechanism either in
the device or in the management system. However, if the device is not being reset, it
remains in the device LOG table. If TRAP is selected, a TRAP via SNMP is generated
and reported via the TRAP's general mechanism. The TRAP can be saved using the
same mechanism.
Falling Threshold—The falling counter value that triggers the falling threshold alarm.
NOTE: The Rising and Falling thresholds are graphically presented on top of the graph bars.
Each monitored variable has a designated color.
Startup Alarm—The trigger that activates the alarm. Rising is defined by crossing the
threshold from a low value threshold to a higher value threshold. The possible field
values are:
Rising Alarm
Falling Alarm
Rising and Falling Alarm
Interval—Indicates the alarm interval time.
Owner—Indicates the device or user that defined the alarm.
Remove—Removes an RMON Alarm.
Check—Removes an Alarm Table entry.
Unchecked—Maintains an Alarm Table entry.
Adding an Alarm Table entry:
Open the RMON Alarm page.
1
Click Add. The New Alarm Entry page opens.
2