Analog Output - Omron ZG User Manual

2d profile measuring sensors
Hide thumbs Also See for ZG:
Table of Contents

Advertisement

Function
Signal
Execute
ZERO-
zero reset
RESET
Measurement
TRIG
trigger

Analog Output

Connect the analog output wire to an external ammeter or voltmeter, and convert the
measurement value for output as 4 to 20 mA analog current or -10 to +10 V analog
voltage. With analog output, output values can be scaled or corrected to suit the
conditions of the connected external device.
Setting Analog Output Conditions p.90
Note
The maximum response in analog output is 500 µs.
ZG User's Manual
Description
Sets the measurement values of all tasks to zero.
• At zero reset execution
Input the zero reset signal for 50 to 800 ms. After the zero reset
execution signal turns OFF, the zero reset is executed within one
measurement cycle.
• At zero reset cancellation
Input the zero reset signal for 1 s or longer. The zero reset is
cancelled within one measurement cycle after 1 s elapses.
Inputs the measurement start/stop timing from an external device.
Communication Using I/O Signals
113