Omron ZG User Manual page 114

2d profile measuring sensors
Hide thumbs Also See for ZG:
Table of Contents

Advertisement

Assignments and Functions of I/O Signal Wires
Assignment of output signal wires
Function
Signal
Judgment
ALL-PASS Turns ON when the judgment result of all tasks is OK (or all tasks
output
NG
ERROR
Trigger
ENABLE
auxiliary
GATE
Assignment of input signal wires
Function
Signal
Bank
BANK A/
switching
BANK B
Stop laser
LD-OFF
112
Communication Using I/O Signals
Description
are not registered).
Turns ON when there is even one task whose judgment result is NG.
Turns ON when there is even one task for which a measurement
error occurred.
Turns ON when trigger input is enabled during trigger measurement.
Turns OFF during bank switching.
Regular During trigger measurement
Trigger
ON
Continuous
ON
Turns ON when the measurement result is being fixed.
(The startup and output times can also be set.)
Description
This is used for switching banks. Specify the bank No. in
combinations of A and B.
Bank Nos. that can be switched by input signal wires are banks 1 to
4. If banks 5 to 16 must be switched, switch by using serial
communication commands or by operating the keys on the
Controller.
Selected bank BANK A
Bank 1
Bank 2
Bank 3
Bank 4
ENABLE output becomes OFF during bank switching. (when a
trigger is enabled)
Bank switching time p.124
Stops laser lighting (emission). While LD-OFF is being input, linear
output and judgment output conform to the non-measurement setting.
Bank switching in progress
OFF
OFF
-
OFF
BANK B
OFF
OFF
ON
OFF
OFF
ON
ON
ON
ZG User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zg seriesZg-wds70Zg-wds22Zg-wds8tZg-wds3t